Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement
- PMID: 26857069
- PMCID: PMC4802434
- DOI: 10.1161/JAHA.115.002866
Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement
Abstract
Background: The aim of this study was to compare left ventricular (LV) remodeling using myocardial strain between patients with severe aortic stenosis (AS) treated with transcatheter aortic valve replacement (TAVR) with and without prosthesis-patient mismatch (PPM).
Methods and results: In a retrospective study, speckle-tracking echocardiography was used to measure global longitudinal strain (GLS) and strain rate (GLSR), circumferential strain, and rotation before and at mid-term follow-up post-TAVR. Moderate and severe PPM were defined as an effective orifice area ≤0.85 and <0.65 cm(2)/m(2), respectively. A total of 102 patients (median age, 83 years [77-88]) with severe AS were included. At 6±3 months post-TAVR, moderate and severe PPM were found in 32 (31%) and 9 (9%) patients. Patients without PPM had a significant regression in LV mass (from 134±41 to 119±38 g/m(2); P=0.001) at follow-up whereas those with PPM did not. There was a significant improvement in LV GLS (-12.8±4.0 to -14.3±4.3%; P=0.01), GLSR (-0.61±0.20 to -0.73±0.25 second(-1); P<0.001), and early diastolic strain rate (0.52±0.20 to 0.64±0.20 second(-1); P<0.001) in patients without PPM, but not in those with PPM. After adjustment for pre-TAVR ejection fraction and post-TAVR aortic regurgitation, patients without PPM had greater improvement in LV longitudinal strain parameters compared to those with PPM. After a median follow-up of 46.1 months (interquartile range, 35.4-60.8), there was no difference in survival between patients with and without PPM.
Conclusions: TAVR was associated with an incidence of PPM of 40%. Greater reverse LV remodeling using myocardial strain was evident in patients without PPM compared to PPM. Presence of PPM was not associated with mortality.
Keywords: aortic stenosis; effective orifice area; prosthesis‐patient mismatch; speckle‐tracking echocardiography; strain; transcatheter aortic valve replacement.
© 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Figures
References
-
- Kodali SK, Williams MR, Smith CR, Svensson LG, Webb JG, Makkar RR, Fontana GP, Dewey TM, Thourani VH, Pichard AD, Fischbein M, Szeto WY, Lim S, Greason KL, Teirstein PS, Malaisrie SC, Douglas PS, Hahn RT, Whisenant B, Zajarias A, Wang D, Akin JJ, Anderson WN, Leon MB. Two‐year outcomes after transcatheter or surgical aortic‐valve replacement. N Engl J Med. 2012;366:1686–1695. - PubMed
-
- Clavel MA, Webb JG, Pibarot P, Altwegg L, Dumont E, Thompson C, De Larochelliere R, Doyle D, Masson JB, Bergeron S, Bertrand OF, Rodes‐Cabau J. Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis. J Am Coll Cardiol. 2009;53:1883–1891. - PubMed
-
- Hahn RT, Pibarot P, Stewart WJ, Weissman NJ, Gopalakrishnan D, Keane MG, Anwaruddin S, Wang Z, Bilsker M, Lindman BR, Herrmann HC, Kodali SK, Makkar R, Thourani VH, Svensson LG, Akin JJ, Anderson WN, Leon MB, Douglas PS. Comparison of transcatheter and surgical aortic valve replacement in severe aortic stenosis: a longitudinal study of echocardiography parameters in cohort A of the PARTNER trial (placement of aortic transcatheter valves). J Am Coll Cardiol. 2013;61:2514–2521. - PMC - PubMed
-
- Kim SJ, Samad Z, Bloomfield GS, Douglas PS. A critical review of hemodynamic changes and left ventricular remodeling after surgical aortic valve replacement and percutaneous aortic valve replacement. Am Heart J. 2014;168:150–159.e1‐7. - PubMed
-
- Pibarot P, Weissman NJ, Stewart WJ, Hahn RT, Lindman BR, McAndrew T, Kodali SK, Mack MJ, Thourani VH, Miller DC, Svensson LG, Herrmann HC, Smith CR, Rodes‐Cabau J, Webb J, Lim S, Xu K, Hueter I, Douglas PS, Leon MB. Incidence and sequelae of prosthesis‐patient mismatch in transcatheter versus surgical valve replacement in high‐risk patients with severe aortic stenosis: a PARTNER trial cohort–a analysis. J Am Coll Cardiol. 2014;64:1323–1334. - PMC - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous
