Absence of coronary sinus tributaries in ischemic cardiomyopathy: An insight from multidetector computed tomography cardiac venographic study
- PMID: 26857422
- DOI: 10.1016/j.jcct.2016.01.015
Absence of coronary sinus tributaries in ischemic cardiomyopathy: An insight from multidetector computed tomography cardiac venographic study
Abstract
Objective: Cardiac resynchronization therapy (CRT) is an important therapeutic strategy in heart failure. However, there is a high incidence of lead implantation failure and suboptimal response, particularly in ischemic cardiomyopathy. This failure rate may partly be secondary to lack of suitable coronary sinus branches for lead implantation. We sought to assess the presence of coronary sinus (CS) tributaries in patients with ischemic and non-ischemic cardiomyopathy.
Materials and methods: Multidetector computed tomography (MDCT) was performed in 100 patients: 25 coronary artery bypass graft (CABG) patients with impaired left ventricular ejection fraction (LVEF), 25 CABG patients with preserved LVEF, 25 patients with non-ischemic cardiomyopathy, and 25 controls. The presence of the CS and its tributaries, including the posterior interventricular vein (PIV), posterolateral vein (PLV), left marginal vein (LMV), and the anterior interventricular vein (AIV) was assessed.
Results: The CS, PIV, and AIV were demonstrated in all patients, whereas presence of a PLV and LMV was identified in 68% and 48% of CABG patients with impaired LVEF, 96% and 68% of CABG patients with preserved LVEF, 92% and 80% of patients with non-ischemic cardiomyopathy, and 100% and 80% of controls (p = 0.001 and 0.046 for PLV and LMV, respectively).
Conclusions: This is the first report to demonstrate that the posterolateral vein and left middle vein, branches of the coronary sinus, are detectable in a significantly smaller number of CABG patients with impaired LVEF compared to controls, CABG with preserved LVEF, and non-ischemic cardiomyopathy. The absence of CS tributary veins in ischemic cardiomyopathy potentially hinders proper lead implantation and results in suboptimal CRT response.
Keywords: Cardiac resynchronization therapy; Computed tomography; Coronary sinus; Heart failure; Ischemic cardiomyopathy.
Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Multidetector cardiac tomography: a useful tool before cardiac resynchronization therapy.Cardiol J. 2015;22(5):590-6. doi: 10.5603/CJ.a2015.0011. Epub 2015 Mar 3. Cardiol J. 2015. PMID: 25733321
-
Non-invasive evaluation of the coronary venous system in patients with chronic systolic heart failure by 64-detector computed tomography.Acta Radiol. 2011 May 1;52(4):372-7. doi: 10.1258/ar.2011.100241. Epub 2011 Mar 24. Acta Radiol. 2011. PMID: 21498314
-
Morphologic and topologic characteristics of coronary venous system delineated by noninvasive multidetector computed tomography in chronic systolic heart failure patients.J Card Fail. 2007 Aug;13(6):482-8. doi: 10.1016/j.cardfail.2007.02.007. J Card Fail. 2007. PMID: 17675063
-
Anomalies of the Coronary Sinus and Its Tributaries: Evaluation on Multidetector Computed Tomography Angiography.J Thorac Imaging. 2020 Mar;35(2):W60-W67. doi: 10.1097/RTI.0000000000000456. J Thorac Imaging. 2020. PMID: 31688460 Review.
-
Coronary venous anatomy and anomalies.J Cardiovasc Comput Tomogr. 2020 Jan-Feb;14(1):80-86. doi: 10.1016/j.jcct.2019.08.006. Epub 2019 Aug 7. J Cardiovasc Comput Tomogr. 2020. PMID: 31444098 Review.
Cited by
-
Morphometry of the Great Cardiac Vein in Cadaveric Hearts of South Indian Origin.Cureus. 2022 Mar 24;14(3):e23460. doi: 10.7759/cureus.23460. eCollection 2022 Mar. Cureus. 2022. PMID: 35371866 Free PMC article.
-
Computed tomography of cardiomyopathies.Cardiovasc Diagn Ther. 2017 Oct;7(5):539-556. doi: 10.21037/cdt.2017.09.07. Cardiovasc Diagn Ther. 2017. PMID: 29255695 Free PMC article. Review.
-
Evaluation of the anatomical variations of the coronary venous system in patients with coronary artery calcification using 256-slice computed tomography.PLoS One. 2020 Nov 18;15(11):e0242216. doi: 10.1371/journal.pone.0242216. eCollection 2020. PLoS One. 2020. PMID: 33206718 Free PMC article.
-
Accuracy of photon-counting detector CT-based iodine maps for myocardial late enhancement detection.Eur Radiol. 2025 May 1. doi: 10.1007/s00330-025-11622-0. Online ahead of print. Eur Radiol. 2025. PMID: 40310540
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials