Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2016 Feb;109(2):87-95.
doi: 10.1016/j.acvd.2015.12.001. Epub 2016 Feb 5.

3D transthoracic echocardiography to assess pulmonary valve morphology and annulus size in patients with Tetralogy of Fallot

Affiliations
Free article
Comparative Study

3D transthoracic echocardiography to assess pulmonary valve morphology and annulus size in patients with Tetralogy of Fallot

Khaled Hadeed et al. Arch Cardiovasc Dis. 2016 Feb.
Free article

Abstract

Background: Accurate evaluation of the pulmonary valve (PV) is crucial before surgical repair of Tetralogy of Fallot (TOF).

Aims: To assess PV and pulmonary annulus (PA) morphology using three-dimensional (3D) transthoracic echocardiography (TTE) in infants referred for surgical repair of TOF. Also, to compare PA measurements obtained by 3D TTE with those from other imaging modalities, including two-dimensional (2D) TTE and computed tomography (CT), with reference to surgical measurements.

Methods: 3D zoom mode was used to assess PV morphology. 2D TTE and CT PA diameters were compared to both vertical and horizontal diameters obtained from 3D datasets. Surgical PA diameters were measured using Hegar's dilators.

Results: A total of 29 patients with TOF (median [range] age 6 [3-24] months) were included and all successfully underwent 2D and 3D TTE; 22 also underwent CT. The number of pulmonary leaflets could be visualized in 24 patients (82.8%), with complete concordance with surgical findings. Vertical diameter was significantly longer than horizontal diameter (P<0.001)-underlying PA eccentricity-and was more important in bicuspid than tricuspid valves. Correlations between 2D and 3D TTE diameters were good. Surgical diameter was better correlated with 2D and 3D diameters than with CT diameter. 3D minimum, 2D and CT diameters were significantly lower than surgical diameters, but 3D mean and maximum diameters were not.

Conclusion: 3D TTE is accurate to assess PV morphology and PA size in patients with TOF. 2D TTE and CT underestimate PA diameter with reference to surgical diameter, however 3D mean and maximum diameters did not differ significantly.

Keywords: Anneau pulmonaire; Cardiac computed tomography; Pulmonary annulus; Pulmonary valve; Scanner cardiaque; Three-dimensional echocardiography; Two-dimensional echocardiography; Valve pulmonaire; Échocardiographie bidimensionnelle; Échocardiographie tridimensionnelle.

PubMed Disclaimer

LinkOut - more resources