An Automatic 3-D Reconstruction of Coronary Arteries by Stereopsis

Affiliations

An Automatic 3-D Reconstruction of Coronary Arteries by Stereopsis

Mufit Cetin et al. J Med Syst. 2016 Apr.

Abstract

Stereopsis of X-ray images can produce 3D tree of coronary arteries up to a certain accuracy level with a lower dose of radiation when compared to computer tomography (CT). In this study, a novel and complete automatic system is designed that covers preprocessing, segmentation, matching and reconstruction steps for that purpose. First, an automatic and novel pattern recognition technique is applied for extraction of the bifurcation points with their diameters recorded in a map. Then, a novel optimization algorithm is run for matching the branches efficiently which is based on that map and the epipolar geometry of stereopsis. Finally, cut branches are fixed one by one at the bifurcations for completing the 3D reconstruction. This method prevails the similar ones in the literature with this novelty since it automatically and inherently prevents the wrong overlapping of branches. Other essential problems like correct detection of the bifurcations and accurate calibration parameters and fast overlapping of matched branches are addressed at acceptable levels. The accuracy of bifurcation extraction is high at 90 % with 96 % sensitivity. Accuracy of vessel centerlines has rootmean-square (rms) error smaller than 0.57 mm for 20 different patients. For phantom model, rms error is 0.75 ± 0.8 mm in 3D localization.

Keywords: Automaticity; Bifurcation; Coronary artery; Medical imaging; Stereopsis.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Magn Reson Imaging. 2011 Sep;34(3):499-510 - PubMed
    1. Int J Cardiovasc Imaging. 2011 Feb;27(2):167-74 - PubMed
    1. Int J Cardiovasc Imaging. 2010 Oct;26(7):733-49 - PubMed
    1. Med Phys. 2008 May;35(5):2124-36 - PubMed
    1. Int J Cardiovasc Imaging. 2010 Jan;26(1):5-17 - PubMed

MeSH terms

LinkOut - more resources