Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Jun;33(6):1327-36.
doi: 10.1007/s11095-016-1874-8. Epub 2016 Feb 11.

Effects of Pump Pulsation on Hydrodynamic Properties and Dissolution Profiles in Flow-Through Dissolution Systems (USP 4)

Affiliations

Effects of Pump Pulsation on Hydrodynamic Properties and Dissolution Profiles in Flow-Through Dissolution Systems (USP 4)

Hiroyuki Yoshida et al. Pharm Res. 2016 Jun.

Abstract

Purpose: To clarify the effects of pump pulsation and flow-through cell (FTC) dissolution system settings on the hydrodynamic properties and dissolution profiles of model formulations.

Methods: Two FTC systems with different cell temperature control mechanisms were used. Particle image velocimetry (PIV) was used to analyze the hydrodynamic properties of test solutions in the flow-through dissolution test cell. Two pulsation pumps (semi-sine, full-sine) and a non-pulsatile pump were used to study the effects of varied flows on the dissolution profiles of United States Pharmacopeia standard tablets.

Results: PIV analysis showed periodic changes in the aligned upward fluid flow throughout the dissolution cell that was designed to reduce the temperature gradient during pump pulsation (0.5 s/pulse). The maximum instantaneous flow from the semi-sine pump was higher than that of the full-sine pump under all conditions. The flow from the semi-sine wave pump showed faster dissolution of salicylic acid and prednisone tablets than those from other pumps. The semi-sine wave pump flow showed similar dissolution profiles in the two FTC systems.

Conclusions: Variations in instantaneous fluid flow caused by pump pulsation that meets the requirements of pharmacopoeias are a factor that affects the dissolution profiles of tablets in FTC systems.

Keywords: dissolution testing; flow-through cell system; hydrodynamics; pulsatile pump.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Boll Chim Farm. 1993 Apr;132(4):105-15 - PubMed
    1. Int J Pharm. 2009 Jul 6;376(1-2):22-40 - PubMed
    1. Int J Pharm. 2011 Oct 31;419(1-2):175-85 - PubMed
    1. Pharm Res. 2010 Feb;27(2):246-58 - PubMed
    1. Pharm Res. 2015 Sep;32(9):2950-9 - PubMed

Publication types

LinkOut - more resources