. 2016 Feb;41(1):6-11.
doi: 10.5395/rde.2016.41.1.6. Epub 2016 Jan 4.

An in vitro evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand files

Affiliations

An in vitro evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand files

Paras Mull Gehlot et al. Restor Dent Endod. 2016 Feb.

Abstract

Objectives: The purpose of this in vitro study was to evaluate the accuracy of working length (WL) determination of four electronic apex locators (EALs), namely, Root ZX (RZX), Elements diagnostic unit and apex locator (ELE), SybronEndo Mini Apex locator (MINI) and Propex pixi (PIXI) using Stainless steel (SS) and nickel-titanium (NiTi) hand files. The null hypothesis was that there was no difference between canal length determination by SS and NiTi files of 4 EALs.

Materials and methods: Sixty extracted, single rooted human teeth were decoronated and the canal orifice flared. The actual length (AL) was assessed visually, and the teeth were embedded in an alginate model. The electronic length (EL) measurements were recorded with all four EALs using SS and NiTi files at '0.5' reading on display. The differences between the AL and EL were compared.

Results: The results obtained with each EAL with SS and NiTi files were compared with AL. A paired sample t test showed that there was a statistical significant difference between EAL readings with SS and NiTi files for RZX and MINI (p < 0.05). The accuracy of RZX, ELE, MINI and PIXI within ± 0.5 mm of AL with SS/NiTi files were 93.3%/70%, 90%/91.7%, 95%/68.3%, and 83.3%/83.3%, respectively.

Conclusions: The results of this study indicate that Root ZX was statistically more accurate with NiTi files compared to SS files, while MINI was statistically more accurate with SS files compared to NiTi files. ELE and PIXI were not affected by the alloy type of the file used to determine WL.

Keywords: Electronic apex locator; Elements Apex locator; Mini Apex Locator; NiTi hand files; Propex pixi; Root ZX.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest: No potential conflict of interest relevant to this article was reported.

Similar articles

Cited by

References

    1. Ingle JI, Backland LK. Endodontics. 5th ed. Loma Linda, California: BC Decker Inc.; 2002. Chapter 10. Endodontic cavity preparation; pp. 510–525.
    1. Kim E, Lee SJ. Electronic apex locator. Dent Clin North Am. 2004;48:35–54. - PubMed
    1. Sunada I. New method for measuring the length of the root canal. J Dent Res. 1962;41:375–387.
    1. Nekoofar MH, Ghandi MM, Hayes SJ, Dummer PM. The fundamental operating principles of electronic root canal length measurement devices. Int Endod J. 2006;39:595–609. - PubMed
    1. Kobayashi C, Suda H. New electronic canal measuring device based on the ratio method. J Endod. 1994;20:111–114. - PubMed