Complications of ultrasonically guided fine-needle abdominal biopsy. Results of a multicenter Italian study and review of the literature. The Cooperative Italian Study Group
- PMID: 2688068
- DOI: 10.3109/00365528909089239
Complications of ultrasonically guided fine-needle abdominal biopsy. Results of a multicenter Italian study and review of the literature. The Cooperative Italian Study Group
Abstract
This report describes the complications following 10,766 ultrasonically guided fine-needle biopsies performed from 1979 to 1987 in 33 Italian echographic units. The mortality was 0.018%: the two reported deaths were due to hemoperitoneum and occurred in patients with hepatocellular carcinoma arising in a cirrhotic liver. Twenty patients (0.18%) had major complications. This series confirms that abdominal biopsy with fine needles is safe, even though our death rate was higher than in previous reports. Among the other nine fatalities following fine-needle abdominal biopsy reported in the literature, seven were secondary to hemorrhage. The biopsy of pancreatic carcinoma was more dangerous for needle-tract seeding (five of eight reported cases, including one in our series).
Similar articles
-
Complications of percutaneous abdominal fine-needle biopsy. Review.Radiology. 1991 Jan;178(1):253-8. doi: 10.1148/radiology.178.1.1984314. Radiology. 1991. PMID: 1984314 Review.
-
Ultrasonically guided fine-needle biopsy in focal intrahepatic lesions: six years' experience.Can Assoc Radiol J. 1986 Mar;37(1):5-8. Can Assoc Radiol J. 1986. PMID: 2422177
-
Ultrasonically-guided fine-needle biopsy of gastrointestinal organs: indications, results and complications.Dig Dis. 1992;10(3):121-33. doi: 10.1159/000171350. Dig Dis. 1992. PMID: 1319288 Review.
-
Needle tract implantation of hepatocellular carcinoma after ultrasonically guided needle liver biopsy: a case report.Hepatogastroenterology. 1995 Sep-Oct;42(5):601-6. Hepatogastroenterology. 1995. PMID: 8751221
-
Diagnosis of hepatic lesions: ultrasonically guided fine needle biopsy or laparoscopy?Gastrointest Endosc. 1988 May-Jun;34(3):231-4. doi: 10.1016/s0016-5107(88)71318-8. Gastrointest Endosc. 1988. PMID: 2839390
Cited by
-
Ultrasound-guided vs endoscopic ultrasound-guided fine-needle aspiration for pancreatic cancer diagnosis.World J Gastroenterol. 2013 Apr 21;19(15):2368-73. doi: 10.3748/wjg.v19.i15.2368. World J Gastroenterol. 2013. PMID: 23613631 Free PMC article.
-
Treatment and clinical outcome of needle-track seeding from hepatocellular carcinoma.Korean J Hepatol. 2011 Jun;17(2):106-12. doi: 10.3350/kjhep.2011.17.2.106. Korean J Hepatol. 2011. PMID: 21757981 Free PMC article.
-
Effectiveness and complications of ultrasound guided fine needle aspiration for primary liver cancer in a Chinese population with serum α-fetoprotein levels ≤200 ng/ml--a study based on 4,312 patients.PLoS One. 2014 Aug 29;9(8):e101536. doi: 10.1371/journal.pone.0101536. eCollection 2014. PLoS One. 2014. PMID: 25170868 Free PMC article.
-
Two cases of lethal complications following ultrasound-guided percutaneous fine-needle biopsy of the liver.Cardiovasc Intervent Radiol. 1996 Sep-Oct;19(5):360-3. doi: 10.1007/BF02570192. Cardiovasc Intervent Radiol. 1996. PMID: 8781161
-
Sonographically guided puncture of the pancreas: incidence of complications, and risk factors.J Med Ultrason (2001). 2013 Jan;40(1):19-26. doi: 10.1007/s10396-012-0376-5. Epub 2012 Jul 4. J Med Ultrason (2001). 2013. PMID: 27276920