Non-invasive assessment of tear film stability with a novel corneal topographer in Indian subjects
- PMID: 26887564
- DOI: 10.1007/s10792-016-0186-7
Non-invasive assessment of tear film stability with a novel corneal topographer in Indian subjects
Abstract
The aim of the study is to investigate the applicability of a newly developed corneal topographer in assessing tear film stability in Indian subjects. A prospective comparative study of 25 Indian subjects with dry eyes attending a tertiary eye care clinic in South India and 25 normal control subjects was conducted. The diagnosis of dry eye was made based on ocular surface disease index questionnaire. Non-invasive tear film break-up time (NI-TBUT) was measured using a new method based on a corneal topographer equipped with modified scan software. The correlations between the NI-TBUT and the traditional fluorescein tear film break-up time (F-TBUT), Schirmer I test values were determined. A total of 50 patients (100 eyes) were included. The values of NI-TBUT were significantly lower than the values of F-TBUT in both the cases (NI-TBUT 5.78 ± 0.8 s and F-TBUT 7.56 ± 0.5 s; p < 0.02) and controls (NI-TBUT 11.66 ± 1 s and F-TBUT 12.92 ± 1.2 s; p < 0.01). NI-TBUT values were significantly lower than the corresponding F-TBUT values in the varying grades of dry eyes. The mean NI-TBUT values in mild dry eyes was 6.42 ± 0.2 s, moderate dry eyes was 4.70 ± 0.3 s and in severe dry eyes was 2.32 ± 1.2 s. There was a significant difference in the NI-TBUT values for cases and controls (p < 0.001). There was a good correlation seen between the NI-TBUT values and the F-TBUT values, Schirmer I values and the ODSI scores. NI-TBUT was found to have a sensitivity of 86.1 % and a specificity of 81.1 % when the cut-off value was kept at 6.2 s. We investigated the performance of a non-invasive technique for measuring tear film stability to aid in the diagnosis of dry eye disease. It is a useful non-invasive objective method for the detection of dry eye, and its varying grades and may be useful in monitoring the efficacy of therapies for dry eye.
Keywords: Corneal topographer; Indian; Non-invasive; TBUT.
Similar articles
-
Assessment of tear film stability in dry eye with a newly developed keratograph.Cornea. 2013 May;32(5):716-21. doi: 10.1097/ICO.0b013e3182714425. Cornea. 2013. PMID: 23132457
-
Regional Differences in Tear Film Stability and Meibomian Glands in Patients With Aqueous-Deficient Dry Eye.Eye Contact Lens. 2016 Jul;42(4):250-5. doi: 10.1097/ICL.0000000000000191. Eye Contact Lens. 2016. PMID: 26383772
-
Comparative Evaluation of Clinical Methods of Tear Film Stability Assessment: A Randomized Crossover Trial.JAMA Ophthalmol. 2018 Mar 1;136(3):291-294. doi: 10.1001/jamaophthalmol.2017.6489. JAMA Ophthalmol. 2018. PMID: 29392287 Free PMC article. Clinical Trial.
-
Tear Film Stability and Tear Break Up Time (TBUT) in Laboratory Rabbits-A Systematic Review.Curr Eye Res. 2018 Aug;43(8):961-964. doi: 10.1080/02713683.2018.1457164. Epub 2018 Apr 9. Curr Eye Res. 2018. PMID: 29630415
-
Tear film analysis and evaluation of optical quality: A review of the literature.J Fr Ophtalmol. 2019 Feb;42(2):e21-e35. doi: 10.1016/j.jfo.2018.12.001. Epub 2019 Jan 22. J Fr Ophtalmol. 2019. PMID: 30679123 Review.
Cited by
-
Smart Eye Camera: A Validation Study for Evaluating the Tear Film Breakup Time in Human Subjects.Transl Vis Sci Technol. 2021 Apr 1;10(4):28. doi: 10.1167/tvst.10.4.28. Transl Vis Sci Technol. 2021. PMID: 34004005 Free PMC article.
-
Reliability and clinical applicability of a novel tear film imaging tool.Graefes Arch Clin Exp Ophthalmol. 2021 Jul;259(7):1935-1943. doi: 10.1007/s00417-021-05162-8. Epub 2021 Mar 29. Graefes Arch Clin Exp Ophthalmol. 2021. PMID: 33779800 Free PMC article.
-
Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population: Implications for Clinical Diagnosis.J Clin Med. 2025 Aug 15;14(16):5794. doi: 10.3390/jcm14165794. J Clin Med. 2025. PMID: 40869620 Free PMC article.
-
Diagnostic Performance of Visionix VX120+ Platform for Dry Eye Screening.Diagnostics (Basel). 2024 Oct 12;14(20):2276. doi: 10.3390/diagnostics14202276. Diagnostics (Basel). 2024. PMID: 39451598 Free PMC article.
-
Comparing automated and manual assessments of tear break-up time using different non-invasive devices and a fluorescein procedure.Sci Rep. 2024 Jan 30;14(1):2516. doi: 10.1038/s41598-024-52686-0. Sci Rep. 2024. PMID: 38291100 Free PMC article. Clinical Trial.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical