Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Aug;35(8):1789-801.
doi: 10.1109/TMI.2016.2529500. Epub 2016 Feb 12.

Automatic Segmentation of Wrist Bones in CT Using a Statistical Wrist Shape + Pose Model

Automatic Segmentation of Wrist Bones in CT Using a Statistical Wrist Shape + Pose Model

Emran Mohammad Abu Anas et al. IEEE Trans Med Imaging. 2016 Aug.

Abstract

Segmentation of the wrist bones in CT images has been frequently used in different clinical applications including arthritis evaluation, bone age assessment and image-guided interventions. The major challenges include non-uniformity and spongy textures of the bone tissue as well as narrow inter-bone spaces. In this work, we propose an automatic wrist bone segmentation technique for CT images based on a statistical model that captures the shape and pose variations of the wrist joint across 60 example wrists at nine different wrist positions. To establish the correspondences across the training shapes at neutral positions, the wrist bone surfaces are jointly aligned using a group-wise registration framework based on a Gaussian Mixture Model. Principal component analysis is then used to determine the major modes of shape variations. The variations in poses not only across the population but also across different wrist positions are incorporated in two pose models. An intra-subject pose model is developed by utilizing the similarity transforms at all wrist positions across the population. Further, an inter-subject pose model is used to model the pose variations across different wrist positions. For segmentation of the wrist bones in CT images, the developed model is registered to the edge point cloud extracted from the CT volume through an expectation maximization based probabilistic approach. Residual registration errors are corrected by application of a non-rigid registration technique. We validate the proposed segmentation method by registering the wrist model to a total of 66 unseen CT volumes of average voxel size of 0.38 mm. We report a mean surface distance error of 0.33 mm and a mean Jaccard index of 0.86.

PubMed Disclaimer

Grants and funding

LinkOut - more resources