Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2016 Jun;32(6):955-63.
doi: 10.1007/s10554-016-0859-3. Epub 2016 Feb 19.

Highly accelerated cardiac MRI using iterative SENSE reconstruction: initial clinical experience

Affiliations
Comparative Study

Highly accelerated cardiac MRI using iterative SENSE reconstruction: initial clinical experience

Bradley D Allen et al. Int J Cardiovasc Imaging. 2016 Jun.

Abstract

To evaluate the qualitative and quantitative performance of an accelerated cardiovascular MRI (CMR) protocol that features iterative SENSE reconstruction and spatio-temporal L1-regularization (IS SENSE). Twenty consecutively recruited patients and 9 healthy volunteers were included. 2D steady state free precession cine images including 3-chamber, 4-chamber, and short axis slices were acquired using standard parallel imaging (GRAPPA, acceleration factor = 2), spatio-temporal undersampled TSENSE (acceleration factor = 4), and IS SENSE techniques (acceleration factor = 4). Acquisition times, quantitative cardiac functional parameters, wall motion abnormalities (WMA), and qualitative performance (scale: 1-poor to 5-excellent for overall image quality, noise, and artifact) were compared. Breath-hold times for IS SENSE (3.0 ± 0.6 s) and TSENSE (3.3 ± 0.6) were both reduced relative to GRAPPA (8.4 ± 1.7 s, p < 0.001). No difference in quantitative cardiac function was present between the three techniques (p = 0.89 for ejection fraction). GRAPPA and IS SENSE had similar image quality (4.7 ± 0.4 vs. 4.5 ± 0.6, p = 0.09) while, both techniques were superior to TSENSE (quality: 4.1 ± 0.7, p < 0.001). GRAPPA WMA agreement with IS SENSE was good (κ > 0.60, p < 0.001), while agreement with TSENSE was poor (κ < 0.40, p < 0.001). IS SENSE is a viable clinical CMR acceleration approach to reduce acquisition times while maintaining satisfactory qualitative and quantitative performance.

Keywords: Accelerated MRI; Cardiac gated imaging techniques; Cardiac magnetic resonance imaging; Ventricular function.

PubMed Disclaimer

References

    1. NMR Biomed. 2006 May;19(3):325-41 - PubMed
    1. J Magn Reson Imaging. 2007 May;25(5):965-73 - PubMed
    1. Magn Reson Med. 2003 Nov;50(5):1031-42 - PubMed
    1. Radiology. 2010 Oct;257(1):71-9 - PubMed
    1. Magn Reson Med. 2014 Feb;71(2):815-22 - PubMed

MeSH terms

LinkOut - more resources