Day by day telemetric care of patients treated with cardiac resynchronisation therapy: first Polish experience
- PMID: 26898970
- DOI: 10.5603/KP.a2016.0019
Day by day telemetric care of patients treated with cardiac resynchronisation therapy: first Polish experience
Abstract
Background: Due to the recent rapid increase in the number of patients implanted with pacemakers, cardioverter-defibrillators (ICD), and cardiac resynchronisation therapy devices (CRT), conventional monitoring at specialist clinics is becoming increasingly difficult. The development of technology has enabled remote device monitoring with the use of teletransmission systems.
Aim: To assess the effectiveness of transmission and the possibility of using telemetric data for further clinical management of patients with heart failure (HF) treated with CRT-D.
Methods: The analysis included 305 consecutive patients with chronic HF, New York Heart Association functional classes II-IV, treated with the use of CRT-D by Biotronik or Medtronic in the years 2006-2012. The patients received transmitters, enabling the remote monitoring of the implanted device from the patients' houses. Scheduled reports were automatically sent every month. The triggers for pre-specified emergency alert transmissions were as follows: ventricular tachycardia (VT) or ventricular fibrillation (VF) episodes, CRT-D intervention, ventricular extrasystoles > 110/h, any episode of atrial fibrillation (AF), atrial flutter (AFL) or supraventricular tachycardia, mean heart rate (HR) during, mean 24-h HR, CRT pacing < 95%, Elective Replacement Indicator, or End Of Service and device malfunction. The all-cause mortality of the study population has been assessed at the end of the follow-up period (mean of 20.5 months).
Results: Devices manufactured by Biotronik were provided to 71% of the study population, while 29% received devices by Medtronic. In 97.3% of cases, the monitors were wireless, fully automatic, and capable of immediate data transmission whenever a pre-specified alert notification was fulfilled. The analysis of long-term outcomes revealed that all-cause mortality of the whole study population was 13%. The effectiveness of report transmission was 98%. During follow-up a total of 31,198 transmissions were received and analysed, which constituted, on average, 4.9 transmissions per patient per month. Among analyses, 30% were reports generated by scheduled remote follow-ups, and 70% were caused by unscheduled device alerts. Correct functioning of the system was confirmed; the quality of the received data was 100%. In 63.9% of patients, decisions based on the information obtained from telemonitoring reports were made to modify the therapy, refer the patients to cardiology or electrophysiology clinics, or hospitalise them urgently. The most common medical reaction was device reprogramming (46.8%). Pharmacotherapy was modified in 33.7% of patients: beta-blocker dose increase (25.9%), anticoagulant treatment inclusion (15.7%), amiodarone inclusion (1.9%), or digoxin inclusion (4.5%). The remaining medical responses were referring patients for atrioventricular junction ablation (8.1%), VT ablation (2.9%), or AF/AFl ablation (1.6%).
Conclusions: Remote monitoring of implantable devices is feasible, safe, and effective in supervising patients with CRT-D devices. Daily-based remote monitoring of a large population of HF patients allows continuous "triage" of high-risk patients and selection of individuals who require urgent intervention.
Keywords: cardiac resynchronisation therapy; heart failure; remote monitoring.
Similar articles
-
[Safety and efficacy of classic ambulatory implantable cardioverter-defibrillator and resynchronisation systems follow-up compared to telemetric follow-up].Pol Merkur Lekarski. 2016 Mar;40(237):153-9. Pol Merkur Lekarski. 2016. PMID: 27088195 Polish.
-
Survival after shock therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy-defibrillator recipients according to rhythm shocked. The ALTITUDE survival by rhythm study.J Am Coll Cardiol. 2013 Oct 29;62(18):1674-1679. doi: 10.1016/j.jacc.2013.04.083. Epub 2013 Jun 27. J Am Coll Cardiol. 2013. PMID: 23810882
-
[Remote monitoring and follow up of implantable cardioverter defibrillators and cardiac resynchronization therapy devices].Arch Cardiol Mex. 2011 Apr-Jun;81(2):93-9. Arch Cardiol Mex. 2011. PMID: 21775242 Spanish.
-
Remote Monitoring of Implantable Cardioverter-Defibrillators, Cardiac Resynchronization Therapy and Permanent Pacemakers: A Health Technology Assessment.Ont Health Technol Assess Ser. 2018 Oct 24;18(7):1-199. eCollection 2018. Ont Health Technol Assess Ser. 2018. PMID: 30443279 Free PMC article. Review.
-
Remote monitoring: Doomed to let down or an attractive promise?Int J Cardiol Heart Vasc. 2019 May 30;24:100380. doi: 10.1016/j.ijcha.2019.100380. eCollection 2019 Sep. Int J Cardiol Heart Vasc. 2019. PMID: 31193998 Free PMC article. Review.
Cited by
-
Cardiac Electronic Devices: Future Directions and Challenges.Med Devices (Auckl). 2020 Sep 25;13:325-338. doi: 10.2147/MDER.S245625. eCollection 2020. Med Devices (Auckl). 2020. PMID: 33061681 Free PMC article. Review.
-
Telemonitoring for heart failure: a meta-analysis.Eur Heart J. 2023 Aug 14;44(31):2911-2926. doi: 10.1093/eurheartj/ehad280. Eur Heart J. 2023. PMID: 37216272 Free PMC article.
-
Telemedical Monitoring Based on Implantable Devices-the Evolution Beyond the CardioMEMS™ Technology.Curr Heart Fail Rep. 2022 Feb;19(1):7-14. doi: 10.1007/s11897-021-00537-8. Epub 2022 Feb 16. Curr Heart Fail Rep. 2022. PMID: 35174451 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous