Validation of Fitbit-Flex as a measure of free-living physical activity in a community-based phase III cardiac rehabilitation population
- PMID: 26907794
- DOI: 10.1177/2047487316634883
Validation of Fitbit-Flex as a measure of free-living physical activity in a community-based phase III cardiac rehabilitation population
Abstract
Background: Accurate physical activity monitoring is important for cardiac patients. Novel activity monitoring devices may enable precise measurement of physical activity. This study aimed to validate Fitbit-Flex against Actigraph accelerometer for monitoring physical activity.
Design: A validation study with a comparative design.
Methods: Cardiac patients and family members participating in community-based exercise programs wore Fitbit-Flex and Actigraph simultaneously over four days to monitor daily step counts and minutes of moderate to vigorous physical activity (MVPA).
Results: Participants (N = 48) comprised 52.1% males, with a mean age of 65.6 ± 6.9 years and 58.9% had a cardiac diagnosis. Fitbit-Flex and Actigraph were significantly correlated in males, females, total participants and cardiac patients for step counts (r = .96; r = .95; r = .95; r = .95), though less so for MVPA (r = .81; r = .65, r = .74; r = .71). As step counts increased the differences between Fitbit-Flex and Actigraph also increased. Fitbit-Flex over-estimated step counts in females (556 steps/day), males (1462 steps/day) and total participants (1038 steps/day) as well as for minutes of MVPA in females (4 min/day), males (15 min/day) and total participants (10 min/day). Fitbit-Flex had high sensitivity and specificity in classifying participants who achieved the recommended physical activity guidelines.
Conclusion: Fitbit-Flex is accurate in assessing attainment of physical activity guideline recommendations and is useful for monitoring physical activity in cardiac patients. The device does, however, slightly over-estimate step counts and MVPA.
Keywords: Actigraph; Coronary heart disease; Fitbit; accelerometer; activity monitor; cardiac rehabilitation; physical activity; validity.
© The European Society of Cardiology 2016.
Similar articles
-
Validity and Reliability of Fitbit Flex for Step Count, Moderate to Vigorous Physical Activity and Activity Energy Expenditure.PLoS One. 2016 Sep 2;11(9):e0161224. doi: 10.1371/journal.pone.0161224. eCollection 2016. PLoS One. 2016. PMID: 27589592 Free PMC article.
-
Comparison of wrist-worn Fitbit Flex and waist-worn ActiGraph for measuring steps in free-living adults.PLoS One. 2017 Feb 24;12(2):e0172535. doi: 10.1371/journal.pone.0172535. eCollection 2017. PLoS One. 2017. PMID: 28234953 Free PMC article.
-
Concurrent validity of the Fitbit for assessing sedentary behavior and moderate-to-vigorous physical activity.BMC Med Res Methodol. 2019 Feb 7;19(1):29. doi: 10.1186/s12874-019-0668-1. BMC Med Res Methodol. 2019. PMID: 30732582 Free PMC article.
-
How many steps/day are enough? For adults.Int J Behav Nutr Phys Act. 2011 Jul 28;8:79. doi: 10.1186/1479-5868-8-79. Int J Behav Nutr Phys Act. 2011. PMID: 21798015 Free PMC article. Review.
-
How consumer physical activity monitors could transform human physiology research.Am J Physiol Regul Integr Comp Physiol. 2017 Mar 1;312(3):R358-R367. doi: 10.1152/ajpregu.00349.2016. Epub 2017 Jan 4. Am J Physiol Regul Integr Comp Physiol. 2017. PMID: 28052867 Free PMC article. Review.
Cited by
-
Optimising Secondary Prevention and Cardiac Rehabilitation for Atherosclerotic Cardiovascular Disease During the COVID-19 Pandemic: A Position Statement From the Cardiac Society of Australia and New Zealand (CSANZ).Heart Lung Circ. 2020 Jul;29(7):e99-e104. doi: 10.1016/j.hlc.2020.04.007. Epub 2020 Apr 30. Heart Lung Circ. 2020. PMID: 32473781 Free PMC article.
-
Self-reported and objectively measured physical activity levels among Hispanic/Latino adults with type 2 diabetes.BMJ Open Diabetes Res Care. 2020 Mar;8(1):e000893. doi: 10.1136/bmjdrc-2019-000893. BMJ Open Diabetes Res Care. 2020. PMID: 32169933 Free PMC article. Clinical Trial.
-
Using Fitness Trackers and Smartwatches to Measure Physical Activity in Research: Analysis of Consumer Wrist-Worn Wearables.J Med Internet Res. 2018 Mar 22;20(3):e110. doi: 10.2196/jmir.9157. J Med Internet Res. 2018. PMID: 29567635 Free PMC article.
-
Validation of the Fitbit Flex in an Acute Post-Cardiac Surgery Patient Population.Physiother Can. 2018 Fall;70(4):314-320. doi: 10.3138/ptc.2017-34. Physiother Can. 2018. PMID: 30745716 Free PMC article.
-
Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review.JMIR Mhealth Uhealth. 2020 Sep 8;8(9):e18694. doi: 10.2196/18694. JMIR Mhealth Uhealth. 2020. PMID: 32897239 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials