Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2016 Apr;154(4):618-25.
doi: 10.1177/0194599816629632. Epub 2016 Feb 23.

Diagnosis of Metastasis to the Thyroid Gland: Comparison of Core-Needle Biopsy and Fine-Needle Aspiration

Affiliations
Comparative Study

Diagnosis of Metastasis to the Thyroid Gland: Comparison of Core-Needle Biopsy and Fine-Needle Aspiration

Sang Hyun Choi et al. Otolaryngol Head Neck Surg. 2016 Apr.

Abstract

Objectives: Early detection and diagnosis of metastasis to the thyroid gland is important. This study aims to evaluate the clinical value of core-needle biopsy (CNB) by comparing the results of CNB and fine-needle aspiration (FNA) in patients with clinically suspected metastasis to the thyroid gland.

Study design: Case series with chart review.

Setting: Tertiary referral practice.

Subjects: Fifty-two thyroid nodules from 52 patients with clinically suspected metastasis to the thyroid gland (mean age, 62.8 years).

Methods: Of these 52 patients, FNA was initially used in 41 patients and CNB in 20 patients (11 patients as the initial approach and 9 patients after inconclusive FNA results). Ultrasound features of metastasis to the thyroid gland were evaluated. The diagnostic performance, repeated diagnostic examination rate, and diagnostic surgery rate were evaluated for FNA and CNB.

Results: Among these 52 patients, 46 were diagnosed with thyroid metastases and 6 were diagnosed with primary thyroid cancer. Common ultrasound features were an ovoid to round shape (58.7%), ill-defined margin (56.5%), hypoechogenicity (65.2%), and no calcifications (87.0%). Core-needle biopsy achieved a significantly higher sensitivity than FNA (100.0% vs 58.6%, P = .008) without any false-negative results. Both the repeated diagnostic examination rate and the diagnostic surgery rate were significantly lower in CNB than in FNA (5.0% vs 46.3%, P = .001, and 5.0% vs 34.1%, P = .013, respectively).

Conclusions: In cases of known rare primary malignancy, nontypical ultrasound features of primary thyroid malignancy, and need for an additional immunohistochemical analysis, CNB may be primarily considered.

Keywords: biopsy; fine needle; large-core needle; metastasis; thyroid; ultrasound.

PubMed Disclaimer

Publication types

LinkOut - more resources