Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2016 Jun;57(6):925-7.
doi: 10.2967/jnumed.115.169987. Epub 2016 Feb 9.

Pharmacokinetics of 99mTc-MAA- and 99mTc-HSA-Microspheres Used in Preradioembolization Dosimetry: Influence on the Liver-Lung Shunt

Affiliations
Free article
Randomized Controlled Trial

Pharmacokinetics of 99mTc-MAA- and 99mTc-HSA-Microspheres Used in Preradioembolization Dosimetry: Influence on the Liver-Lung Shunt

Oliver S Grosser et al. J Nucl Med. 2016 Jun.
Free article

Abstract

Perfusion scintigraphy using (99m)Tc-labeled albumin aggregates is mandatory before hepatic radioembolization with (90)Y-microspheres. As part of a prospective trial, the intrahepatic and intrapulmonary stability of 2 albumin compounds, (99m)Tc-MAA (macroaggregated serum albumin [MAA]) and (99m)Tc-HSA (human serum albumin [HSA]), was assessed.

Methods: In 24 patients with metastatic colorectal cancer, biodistribution (liver, lung) and liver-lung shunt (LLS) of both tracers (12 patients each) were assessed by sequential planar scintigraphy (1, 5, and 24 h after injection).

Results: Liver uptake of both albumin compounds decreased differently. Although initial LLSs at 1 h after injection were similar in both groups, MAA-LLS increased significantly from 1 (3.9%) to 5 h (7.7%) and 24 h (9.9%) after injection, respectively. HSA-LLS did not change significantly (1 to 5 h), indicating a steady state of pulmonary and intrahepatic degradation.

Conclusion: Compared with (99m)Tc-MAA-microspheres, (99m)Tc-HSA-microspheres are likely more resistant to degradation over time, allowing a reliable LLS determination even at later time points.

Keywords: 99mTc-labeled albumin spheres; biokinetics; dosimetry; liver-lung shunt; radioembolization.