A rapid method for the separation of vitamin D and its metabolites by ultra-high performance supercritical fluid chromatography-mass spectrometry
- PMID: 26931428
- DOI: 10.1016/j.chroma.2016.02.043
A rapid method for the separation of vitamin D and its metabolites by ultra-high performance supercritical fluid chromatography-mass spectrometry
Abstract
In this study, a new supercritical fluid chromatography-mass spectrometry (SFC-MS) method has been developed for the separation of nine vitamin D metabolites within less than eight minutes. This is the first study of analysis of vitamin D and its metabolites carried out by SFC-MS. Six columns of orthogonal selectivity were examined, and the best separation was obtained by using a 1-aminoanthracene (1-AA) column. The number and the position of hydroxyl groups in the structure of the studied compounds as well as the number of unsaturated bonds determine the physiochemical properties and, thus the separation of vitamin D metabolites that is achieved on this column. All D2 and the D3 forms were baseline separated with resolution values>1.5. The effects of pressure, temperature, flow rate and different gradient modes were studied. Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) were compared in positive mode, both by direct infusion and after SFC separation. The results showed that the sensitivity in APCI(+) was higher than in ESI(+) using direct infusion. In contrast, the sensitivity in APCI(+) was 6-fold lower than in ESI(+) after SFC separation. The SFC-MS method was validated between 10 and 500ng/mL for all analytes with coefficient of determination (R(2))≥0.999 for all calibration curves. The limits of detection (LOD) were found to range between 0.39 and 5.98ng/mL for 24,25-dihydroxyvitamin D3 (24,25(OH)2D3) and 1-hydroxyvitamin D2 (1OHD2), respectively. To show its potential, the method was applied to human plasma samples from healthy individuals. Vitamin D3 (D3), 25-hydroxyvitamin D3 (25OHD3) and 24,25(OH)2D3 were determined in plasma samples and the concentrations were 6.6±3.0ng/mL, 23.8±9.2ng/mL and 5.4±2.7ng/mL, respectively.
Keywords: Mass spectrometry; Method development; Orthogonal column screening; Plasma; Ultra-high performance supercritical fluid chromatography; Vitamin D(2) and D(3) metabolites.
Copyright © 2016 Elsevier B.V. All rights reserved.
Similar articles
-
A fast and sensitive method for the separation of carotenoids using ultra-high performance supercritical fluid chromatography-mass spectrometry.Anal Bioanal Chem. 2016 Aug;408(21):5883-5894. doi: 10.1007/s00216-016-9707-5. Epub 2016 Jun 27. Anal Bioanal Chem. 2016. PMID: 27349917
-
Determination of vitamin D in oily drops using a column-switching system with an on-line clean-up by supercritical fluid chromatography.Talanta. 2018 Dec 1;190:9-14. doi: 10.1016/j.talanta.2018.07.063. Epub 2018 Jul 20. Talanta. 2018. PMID: 30172547
-
Analysis of vitamin D and its metabolites in biological samples - Part I: Optimization and comparison of UHPSFC-MS/MS and UHPLC-MS/MS methods.J Chromatogr B Analyt Technol Biomed Life Sci. 2024 Apr 15;1237:124087. doi: 10.1016/j.jchromb.2024.124087. Epub 2024 Mar 12. J Chromatogr B Analyt Technol Biomed Life Sci. 2024. PMID: 38513431
-
Hyphenation of packed column supercritical fluid chromatography with mass spectrometry: where are we and what are the remaining challenges?Anal Bioanal Chem. 2020 Oct;412(25):6667-6677. doi: 10.1007/s00216-020-02715-4. Epub 2020 May 30. Anal Bioanal Chem. 2020. PMID: 32474724 Review.
-
A technical overview of supercritical fluid chromatography-mass spectrometry (SFC-MS) and its recent applications in pharmaceutical research and development.Drug Discov Today Technol. 2021 Dec;40:69-75. doi: 10.1016/j.ddtec.2021.10.002. Epub 2021 Oct 27. Drug Discov Today Technol. 2021. PMID: 34916026 Review.
Cited by
-
Simultaneous Determination of Vitamin D and Its Hydroxylated and Esterified Metabolites by Ultrahigh-Performance Supercritical Fluid Chromatography-Tandem Mass Spectrometry.Anal Chem. 2022 Feb 22;94(7):3065-3073. doi: 10.1021/acs.analchem.1c04016. Epub 2022 Feb 9. Anal Chem. 2022. PMID: 35138814 Free PMC article.
-
Determination of ergocalciferol in human plasma after Diels-Alder derivatization by LC-MS/MS and its application to a bioequivalence study.J Pharm Anal. 2017 Dec;7(6):417-422. doi: 10.1016/j.jpha.2017.05.006. Epub 2017 May 19. J Pharm Anal. 2017. PMID: 29404069 Free PMC article.
-
High Throughput Semiquantitative UHPSFC-MS/MS Lipid Profiling and Lipid Class Determination.J Chromatogr Sci. 2021 Jun 21;59(7):670-680. doi: 10.1093/chromsci/bmaa121. J Chromatogr Sci. 2021. PMID: 33479755 Free PMC article.
-
Quantitative analysis of vitamin D and its main metabolites in human milk by supercritical fluid chromatography coupled to tandem mass spectrometry.Anal Bioanal Chem. 2020 Jan;412(2):365-375. doi: 10.1007/s00216-019-02248-5. Epub 2019 Dec 12. Anal Bioanal Chem. 2020. PMID: 31832707 Free PMC article.
-
[Determination of vitamin D and 25-hydroxyvitamin D in animal-derived foods by derivatization-ultra performance liquid chromatography-tandem mass spectrometry].Se Pu. 2025 Mar;43(3):228-236. doi: 10.3724/SP.J.1123.2024.02003. Se Pu. 2025. PMID: 40045644 Free PMC article. Chinese.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical