. 2016 Sep;11(9):1731-41.
doi: 10.1007/s11548-016-1357-8. Epub 2016 Mar 1.

Quantitative analysis of the patellofemoral motion pattern using semi-automatic processing of 4D CT data

Affiliations

Quantitative analysis of the patellofemoral motion pattern using semi-automatic processing of 4D CT data

Daniel Forsberg et al. Int J Comput Assist Radiol Surg. 2016 Sep.

Abstract

Purpose: To present a semi-automatic method with minimal user interaction for quantitative analysis of the patellofemoral motion pattern.

Methods: 4D CT data capturing the patellofemoral motion pattern of a continuous flexion and extension were collected for five patients prone to patellar luxation both pre- and post-surgically. For the proposed method, an observer would place landmarks in a single 3D volume, which then are automatically propagated to the other volumes in a time sequence. From the landmarks in each volume, the measures patellar displacement, patellar tilt and angle between femur and tibia were computed.

Results: Evaluation of the observer variability showed the proposed semi-automatic method to be favorable over a fully manual counterpart, with an observer variability of approximately 1.5[Formula: see text] for the angle between femur and tibia, 1.5 mm for the patellar displacement, and 4.0[Formula: see text]-5.0[Formula: see text] for the patellar tilt. The proposed method showed that surgery reduced the patellar displacement and tilt at maximum extension with approximately 10-15 mm and 15[Formula: see text]-20[Formula: see text] for three patients but with less evident differences for two of the patients.

Conclusions: A semi-automatic method suitable for quantification of the patellofemoral motion pattern as captured by 4D CT data has been presented. Its observer variability is on par with that of other methods but with the distinct advantage to support continuous motions during the image acquisition.

Keywords: 4D; Computed tomography; Motion pattern; Patella luxation; Quantitative.

PubMed Disclaimer

References

    1. J Digit Imaging. 2010 Dec;23 (6):793-805 - PubMed
    1. Knee Surg Sports Traumatol Arthrosc. 2011 Feb;19(2):230-5 - PubMed
    1. J Bone Joint Surg Br. 2007 Jun;89(6):709-16 - PubMed
    1. J Orthop Res. 1990 May;8(3):372-82 - PubMed
    1. Radiol Phys Technol. 2010 Jul;3(2):151-8 - PubMed

LinkOut - more resources