Performance of High-Flow-Rate Samplers for Respirable Crystalline Silica Measurement Under Field Conditions: Preliminary Study

Affiliations

Performance of High-Flow-Rate Samplers for Respirable Crystalline Silica Measurement Under Field Conditions: Preliminary Study

Marie A Coggins et al. Silica Assoc Respirable Miner Part (2012). 2014 Jan.

Abstract

Restoration stone work regularly involves work with high-silica-content materials (e.g., sandstone), but low-silica-content materials (<2 % quartz) such as limestone and lime mortar are also used. A combination of short sample duration and low silica content makes the quantification of worker exposure to respirable crystalline silica (RCS) difficult. This problem will be further compounded by the introduction of lower occupational exposure standards for RCS. The objective of this work was to determine whether higher-flow samplers might be an effective tool in characterizing lower RCS concentrations. A short study was performed to evaluate the performance of three high-flow samplers (FSP10, CIP10-R, and GK2.69) using side-by-side sampling with low-flow samplers (SIMPEDS and 10-mm nylon cyclones) for RCS exposure measurement at a restoration stonemasonry field site. A total of 19 side-by-side sample replicates for each high-flow and low-flow sampler pair were collected from work tasks involving limestone and sandstone.

Results: Most of the RCS (quartz) masses collected with the high-flow-rate samplers were above the limit of detection (62 % to 84 %) relative to the low-flow-rate samplers (58 % to 78 %). The average of the respirable mass concentration ratios for CIP10-R/SIMPEDS, GK2.69/10-mm nylon, FSP10/SIMPEDS, and FSP10/10-mm nylon pairs and the range of the quartz concentration ratios for the CIP10-R/SIMPEDS, CIP10-R/10-mm nylon, GK2.69/10-mm nylon, FSP10/SIMPEDS, and FSP10/10-mm nylon pairs included unity with an average close to unity, indicating no likely difference between the reported values for each sampler. Workers reported problems related to the weight of the sampling pumps for the high-flow-rate samplers. Respirable mass concentration data suggest that the high-flow-rate samplers evaluated would be appropriate for sampling respirable dust concentrations during restoration stone work. Results from the comparison of average quartz concentration ratios between high-and low-flow samplers suggest that the higher mass collected by the high-flow-rate samplers did not interfere with the quartz measurement. A sig-nificant portion of the data collected with the high-flow-rate samplers (>82 %) were greater than the limit of detection, which indicates that these samplers are suitable for quantifying exposures, even with low-quartz materials.

Keywords: Occupational exposure assessment; Respirable crystalline silica; Stone masonry.

PubMed Disclaimer

Figures

FIG. 1
FIG. 1
Restoration stonemason wearing the FSP-10 paired with the SIMPEDS cyclone, close by on the tripod, CIP10-R/SIMPEDS and GK2.69/SIMPEDS sampler combinations.
FIG. 2
FIG. 2
Scatter plot of quartz masses collected with the CIP10-R, GK2.69, FSP10, SIMPEDS cyclone, and 10-mm nylon cyclone samplers, showing an LOQ of 20 μg and an LOD of 6 μg from NMAM 7500.

References

    1. Kullman GJ, Greife AL, Costello J, Hearl FJ. Occupational Exposures to Fibers and Quartz at 19 Crushed Stone Mining and Milling Operations. Am J Ind Med. 1995;27(5):641–660. - PubMed
    1. Seaton A, Cherrie JW. Quartz Exposures and Severe Silicosis: A Role for the Hilar Nodes. J Occup Environ Med. 1998;55(6):383–386. - PMC - PubMed
    1. Lumens MEGL, Spee T. Determinants of Exposure to Respirable Quartz Dust in the Construction Industry. Ann Occup Hyg. 2001;45:585–595. - PubMed
    1. Linch KD. Respirable Concrete Dust—Silicosis Hazard in the Construction Industry. Appl Occup Environ Hyg. 2002;17(3):209–221. - PubMed
    1. Flanagan ME, Seixas N, Becker P, Takacs B, Camp J. Silica Exposure on Construction Sites: Results of an Exposure Monitoring Data Compilation Project. J Occup Environ Hyg. 2006;3(3):144–152. - PubMed

LinkOut - more resources