Comparative Study
. 2016 Jun;23(3):348-61.
doi: 10.1007/s12350-015-0367-1. Epub 2016 Mar 8.

Comparison of biventricular ejection fractions using cadmium-zinc-telluride SPECT and planar equilibrium radionuclide angiography

Affiliations
Comparative Study

Comparison of biventricular ejection fractions using cadmium-zinc-telluride SPECT and planar equilibrium radionuclide angiography

Yi-Chieh Chen et al. J Nucl Cardiol. 2016 Jun.

Abstract

Background: We compared biventricular ejection fractions (EFs) from gated blood-pool single-photon emission computed tomography (SPECT) using a cadmium-zinc-telluride camera (CZT-SPECT) with planar equilibrium radionuclide angiography (ERNA) using a NaI gamma camera (NaI-planar). We also evaluated whether imaging time can be reduced without compromising image quality using the CZT camera.

Methods: Forty-eight patients underwent NaI-planar and CZT-SPECT on the same day. CZT-SPECT datasets were re-projected at an LAO orientation similar to ERNA acquisition, forming CZT-repro planar datasets. The resulting biventricular volumetric measurements and EFs were compared.

Results: LVEF calculated from CZT-SPECT and CZT-repro correlated better with NaI-planar (r = 0.93 and 0.99, respectively) than RVEF (r = 0.76 and 0.82, respectively). Excellent intra-class correlation and low bias in intra-observer comparisons were observed for the biventricular EFs derived from three datasets. A wider limit of agreement in CZT-SPECT-derived LVEFs, lower correlation and significant bias for NaI-planar, and CZT-repro-derived RVEFs was found in the inter-observer analyses. Nonetheless, the imaging time can be reduced to 4 minutes without increasing variability in EFs using the CZT camera (P = NS).

Conclusions: LVEFs calculated from CZT-SPECT and CZT-repro correlated well with NaI-planar. CZT camera may reduce imaging time while preserving image quality in the assessment of biventricular EFs.

Keywords: Cadmium-zinc-telluride camera; gated blood-pool SPECT; planar equilibrium radionuclide angiography; ventricular ejection fractions.

PubMed Disclaimer

Comment in

References

    1. Clin Physiol Funct Imaging. 2015 Nov;35(6):418-24 - PubMed
    1. Nucl Med Commun. 2011 Feb;32(2):121-8 - PubMed
    1. J Nucl Cardiol. 2006 Nov;13(6):e56-79 - PubMed
    1. Am J Med. 1987 Jun;82(6):1109-18 - PubMed
    1. J Nucl Cardiol. 2011 Aug;18(4):642-9 - PubMed

LinkOut - more resources