DWI at MR Enterography for Evaluating Bowel Inflammation in Crohn Disease
- PMID: 26959382
- DOI: 10.2214/AJR.15.15862
DWI at MR Enterography for Evaluating Bowel Inflammation in Crohn Disease
Abstract
Objective: The purpose of this article is to provide a comprehensive review regarding DWI enterography used for evaluating Crohn disease and to summarize the relevant evidence.
Conclusion: Active bowel inflammation in Crohn disease causes restricted diffusion on MR enterography with DWI. Enterographic DWI to evaluate Crohn disease is increasingly drawing attention for both academic research and clinical practice and has shown potential as a quantitative tool for assessing bowel inflammation. DWI enterography also has multiple unresolved issues and limitations.
Keywords: Crohn disease; DWI; MR enterography; diffusion; inflammatory bowel disease.
Similar articles
-
Value of diffusion-weighted imaging when added to magnetic resonance enterographic evaluation of Crohn disease in children.Pediatr Radiol. 2016 Jan;46(1):34-42. doi: 10.1007/s00247-015-3438-1. Epub 2015 Aug 4. Pediatr Radiol. 2016. PMID: 26238966
-
MR Enterography for the Evaluation of Small-Bowel Inflammation in Crohn Disease by Using Diffusion-weighted Imaging without Intravenous Contrast Material: A Prospective Noninferiority Study.Radiology. 2016 Mar;278(3):762-72. doi: 10.1148/radiol.2015150809. Epub 2015 Sep 8. Radiology. 2016. PMID: 26348103
-
Quantification of inflammatory activity in patients with Crohn's disease using diffusion weighted imaging (DWI) in MR enteroclysis and MR enterography.Acta Radiol. 2017 Mar;58(3):264-271. doi: 10.1177/0284185116648503. Epub 2016 Jul 12. Acta Radiol. 2017. PMID: 27178031
-
New magnetic resonance imaging modalities for Crohn disease.Magn Reson Imaging Clin N Am. 2014 Feb;22(1):35-50. doi: 10.1016/j.mric.2013.07.005. Epub 2013 Sep 17. Magn Reson Imaging Clin N Am. 2014. PMID: 24238131 Review.
-
Magnetic Resonance Enterography in Crohn׳s Disease.Semin Ultrasound CT MR. 2016 Aug;37(4):282-91. doi: 10.1053/j.sult.2016.02.001. Epub 2016 Feb 16. Semin Ultrasound CT MR. 2016. PMID: 27342892 Review.
Cited by
-
Comparison between Diffusion-Weighted Sequences with Selective and Non-Selective Fat Suppression in the Evaluation of Crohn's Disease Activity: Are They Equally Useful?Diagnostics (Basel). 2020 May 27;10(6):347. doi: 10.3390/diagnostics10060347. Diagnostics (Basel). 2020. PMID: 32471191 Free PMC article.
-
Is the Mixed Use of Magnetic Resonance Enterography and Computed Tomography Enterography Adequate for Routine Periodic Follow-Up of Bowel Inflammation in Patients with Crohn's Disease?Korean J Radiol. 2022 Jan;23(1):30-41. doi: 10.3348/kjr.2021.0072. Epub 2021 Sep 13. Korean J Radiol. 2022. PMID: 34564963 Free PMC article.
-
Potential of diffusion-weighted imaging in magnetic resonance enterography to identify neoplasms in the ileocecal region: Use of ultra-high b-value diffusion-weighted imaging.Oncol Lett. 2019 Aug;18(2):1451-1457. doi: 10.3892/ol.2019.10441. Epub 2019 Jun 5. Oncol Lett. 2019. PMID: 31423210 Free PMC article.
-
Diffusion-weighted imaging in Crohn's disease.Radiologie (Heidelb). 2023 Nov;63(Suppl 2):27-33. doi: 10.1007/s00117-023-01191-y. Epub 2023 Aug 21. Radiologie (Heidelb). 2023. PMID: 37603068 Review. English.
-
Lung function imaging methods in Cystic Fibrosis pulmonary disease.Respir Res. 2017 May 17;18(1):96. doi: 10.1186/s12931-017-0578-x. Respir Res. 2017. PMID: 28514950 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical