Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2016 Apr;85(4):808-14.
doi: 10.1016/j.ejrad.2016.01.004. Epub 2016 Jan 16.

Impact on the recall rate of digital breast tomosynthesis as an adjunct to digital mammography in the screening setting. A double reading experience and review of the literature

Affiliations
Comparative Study

Impact on the recall rate of digital breast tomosynthesis as an adjunct to digital mammography in the screening setting. A double reading experience and review of the literature

Luca A Carbonaro et al. Eur J Radiol. 2016 Apr.

Abstract

Objectives: To estimate the impact on recall rate (RR) of digital breast tomosynthesis (DBT) associated with digital mammography (DM+DBT), compared to DM alone, evaluate the impact of double reading (DR) and review the literature.

Methods: Ethics committees approved this multicenter study. Patients gave informed consent. Women recalled from population-based screening reading were included. Reference standard was histology and/or ≥ 1 year follow up. Negative multiple assessment was considered for patients lost at follow up. Two blinded readers (R1, R2) evaluated first DM and subsequently DM+DBT. RR, sensitivity, specificity, accuracy, positive and negative predictive values (PPV, NPV), were calculated for R1, R2, and DR. Cohen κ and χ(2) were used for R1-R2 agreement and RR related to breast density.

Results: We included 280 cases (41 malignancies, 66 benign lesions, and 173 negative examinations). The RR reduction was 43% (R1), 58% (R2), 43% (DR). Sensitivity, specificity, accuracy, PPV and NPV were: 93%, 67%, 71%, 33%, 98% for R1; 88%, 73%, 75%, 36%, 97% for R2; 98%, 55%, 61%, 27%, 99% for DR. The agreement was higher for DM+DBT (κ=0.459 versus κ=0.234). Reduction in RR was independent from breast density (p=0.992).

Conclusion: DBT was confirmed to reduce RR, as shown by 13 of 15 previous studies (reported reduction 6-82%, median 31%). This reduction is confirmed when using DR. DBT allows an increased inter-reader agreement.

Keywords: Breast cancer; Digital breast tomosynthesis (DBT); Digital mammography (DM); Recall rate; Screening; population based.

PubMed Disclaimer

MeSH terms