Effect of Off-Axis Fluoroscopy Imaging on Two-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study
- PMID: 26974192
- PMCID: PMC4843847
- DOI: 10.1115/1.4032995
Effect of Off-Axis Fluoroscopy Imaging on Two-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study
Abstract
Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion-extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar-sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2-S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17-0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion-extension are likely robust, even when patient alignment is not perfect.
Figures





Similar articles
-
Capturing three-dimensional in vivo lumbar intervertebral joint kinematics using dynamic stereo-X-ray imaging.J Biomech Eng. 2014 Jan;136(1):011004. doi: 10.1115/1.4025793. J Biomech Eng. 2014. PMID: 24149991
-
Advanced template matching method for estimation of intervertebral kinematics of lumbar spine.Med Eng Phys. 2011 Dec;33(10):1293-302. doi: 10.1016/j.medengphy.2011.06.009. Epub 2011 Jul 18. Med Eng Phys. 2011. PMID: 21764624
-
Midlumbar lateral flexion stability measured in healthy volunteers by in vivo fluoroscopy.Spine (Phila Pa 1976). 2009 Oct 15;34(22):E811-7. doi: 10.1097/BRS.0b013e3181b1feba. Spine (Phila Pa 1976). 2009. PMID: 19829245
-
In vivo cervical vertebrae kinematic studies based on dual fluoroscopic imaging system measurement: A narrative review.Heliyon. 2024 May 8;10(10):e30904. doi: 10.1016/j.heliyon.2024.e30904. eCollection 2024 May 30. Heliyon. 2024. PMID: 38765031 Free PMC article. Review.
-
Application of Ultrasound in Spine Kinematic Determination: A Systemic Review.J Med Ultrasound. 2022 Feb 24;30(1):6-10. doi: 10.4103/jmu.jmu_200_21. eCollection 2022 Jan-Mar. J Med Ultrasound. 2022. PMID: 35465585 Free PMC article. Review.
Cited by
-
Automated radiographic metrics for diagnosing lumbar spine instability: a cross-sectional observational study.Quant Imaging Med Surg. 2025 Apr 1;15(4):3048-3063. doi: 10.21037/qims-24-1931. Epub 2025 Mar 24. Quant Imaging Med Surg. 2025. PMID: 40235795 Free PMC article.
-
OPF/PMMA cage system as an alternative approach for the treatment of vertebral corpectomy.Appl Sci (Basel). 2020 Oct;10(19):6912. doi: 10.3390/app10196912. Epub 2020 Oct 2. Appl Sci (Basel). 2020. PMID: 33986953 Free PMC article.
-
Definition of Normal Vertebral Morphometry Using NHANES-II Radiographs.JBMR Plus. 2022 Sep 27;6(10):e10677. doi: 10.1002/jbm4.10677. eCollection 2022 Oct. JBMR Plus. 2022. PMID: 36248278 Free PMC article.
-
Analysis of translation and angular motion in loaded and unloaded positions in the lumbar spine.N Am Spine Soc J. 2020 Nov 20;4:100038. doi: 10.1016/j.xnsj.2020.100038. eCollection 2020 Dec. N Am Spine Soc J. 2020. PMID: 35141606 Free PMC article.
-
Does the neutral zone quantification method matter? Efficacy of evaluating neutral zone during destabilization and restabilization in human spine implant testing.J Biomech. 2021 Dec 2;129:110756. doi: 10.1016/j.jbiomech.2021.110756. Epub 2021 Sep 21. J Biomech. 2021. PMID: 34619461 Free PMC article.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous