Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Jun;111(6):823-33.
doi: 10.1038/ajg.2016.56. Epub 2016 Mar 15.

Magnetic Resonance Elastography for the Evaluation of Liver Fibrosis in Chronic Hepatitis B and C by Using Both Gradient-Recalled Echo and Spin-Echo Echo Planar Imaging: A Prospective Study

Affiliations

Magnetic Resonance Elastography for the Evaluation of Liver Fibrosis in Chronic Hepatitis B and C by Using Both Gradient-Recalled Echo and Spin-Echo Echo Planar Imaging: A Prospective Study

Yu Shi et al. Am J Gastroenterol. 2016 Jun.

Abstract

Objectives: Magnetic resonance elastography (MRE) with three-dimensional spin-echo echo planar imaging (3D-SE-EPI) is a newly emerging noninvasive method for assessing liver fibrosis. We hypothesized that 3D-SE-EPI might have better diagnostic accuracy than conventional two-dimensional gradient-recalled echo (2D-GRE).

Methods: We prospectively included 179 consecutive patients with chronic hepatitis B (CHB) or C (CHC) who underwent both MRE and liver biopsy. Liver stiffness was measured by both 3D-SE-EPI and 2D-GRE for staging biopsy-proven liver fibrosis (using METAVIR scores). A receiver-operating characteristic analysis using the area under the receiver-operating characteristic curve (AUC) was used to compare the diagnostic performance in predicting liver fibrosis between these two techniques, and compared them to serum markers of fibrosis.

Results: The technical failure rate of 3D-SE-EPI (2.2%, n=4/179) was lower compared with 2D-GRE (8.3%, n=15/179). The stiffness measured by 3D-SE-EPI was slightly lower compared with 2D-GRE, with the mean difference of 0.57 kPa (Bland and Altman plot, 95% limits of agreement: -0.32 and 1.45 kPa). AUCs for the characterization of ≥F1, ≥F2, ≥F3, and F4 were 0.957 (95% confidence interval (CI): 0.913-0.983), 0.971 (0.932-0.991), 0.991 (0.961-0.999), and 0.979 (0.942-0.995) for 3D-SE-EPI, which was slightly higher compared with the AUCs for 2D-GRE at each fibrosis stage (0.948 (0.901-0.977), 0.959 (0.915-0.981), 0.979 (0.943-0.995), and 0.976 (0.938-0.994), respectively), although none reached statistical significance (P=0.160-0.585). In an "intention-to-diagnose" analysis, the diagnostic accuracy (the proportion of well-classified patients) by EPI (86.7-91.3%, n=169) was higher compared with GRE (80.9-82.1%, n=158) after applying optimal cutoffs. Both 3D-SE-EPI and 2D-GRE performed better than serum fibrosis markers.

Conclusions: With respect to 2D-GRE, 3D-SE-EPI has the advantage of lower failure rate with equivalent high diagnostic performance for staging liver fibrosis in CHB/CHC patients, and thus more helpful for those challenging cases in 2D-GRE.

PubMed Disclaimer

Comment in

References

    1. Radiology. 2014 Oct;273(1):88-98 - PubMed
    1. Liver Int. 2013 Mar;33(3):428-38 - PubMed
    1. J Magn Reson Imaging. 2010 Mar;31(3):725-31 - PubMed
    1. Radiology. 2016 Jan;278(1):114-24 - PubMed
    1. Jpn J Radiol. 2010 Oct;28(8):623-7 - PubMed

Publication types

LinkOut - more resources