Influence of pH, bleaching agents, and acid etching on surface wear of bovine enamel
- PMID: 27008254
- PMCID: PMC4775006
- DOI: 10.1590/1678-775720150281
Influence of pH, bleaching agents, and acid etching on surface wear of bovine enamel
Abstract
Development of new materials for tooth bleaching justifies the need for studies to evaluate the changes in the enamel surface caused by different bleaching protocols.
Objective: The aim of this study was to evaluate the bovine dental enamel wear in function of different bleaching gel protocols, acid etching and pH variation.
Material and methods: Sixty fragments of bovine teeth were cut, obtaining a control and test areas. In the test area, one half received etching followed by a bleaching gel application, and the other half, only the bleaching gel. The fragments were randomly divided into six groups (n=10), each one received one bleaching session with five hydrogen peroxide gel applications of 8 min, activated with hybrid light, diode laser/blue LED (HL) or diode laser/violet LED (VHL) (experimental): Control (C); 35% Total Blanc Office (TBO35HL); 35% Lase Peroxide Sensy (LPS35HL); 25% Lase Peroxide Sensy II (LPS25HL); 15% Lase Peroxide Lite (LPL15HL); and 10% hydrogen peroxide (experimental) (EXP10VHL). pH values were determined by a pHmeter at the initial and final time periods. Specimens were stored, subjected to simulated brushing cycles, and the superficial wear was determined (μm). ANOVA and Tukey´s tests were applied (α=0.05).
Results: The pH showed a slight decrease, except for Group LPL15HL. Group LPS25HL showed the highest degree of wear, with and without etching.
Conclusion: There was a decrease from the initial to the final pH. Different bleaching gels were able to increase the surface wear values after simulated brushing. Acid etching before bleaching increased surface wear values in all groups.
Figures




References
-
- Andreatta LM, Soares AF, Bombonatti JF, Furuse AY, Mondelli RF. Influence of whitening gel and light source on pulp chamber temperature. RSBO. 2015;12(2):185–190.
-
- Bortolatto J, Pretel H, Neto C, Andrade M, Moncada G, Oliveira O., Junior Effects of LED-laser hybrid light on bleaching effectiveness and tooth sensitivity: a randomized clinical study. Laser Phys Lett. 2013;10(8):1–6.
-
- Buchalla W, Attin T, Hellwig E. Brushing abrasion of luting cements under neutral and acidic conditions. Oper Dent. 2000;25(6):482–487. - PubMed
-
- Cartagena AF, Parreiras SO, Loguercio AD, Reis A, Campanha NH. In-office bleaching effects on the pulp flow and tooth sensitivity - case series. [cited 2015 Oct 27];Braz Oral Res. [Internet] 2015 29(1):1–6. http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242015000... - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources