. 2016 Nov;54(11):1793-1806.
doi: 10.1007/s11517-016-1469-x. Epub 2016 Mar 25.

A parameterized logarithmic image processing method with Laplacian of Gaussian filtering for lung nodule enhancement in chest radiographs

Affiliations

A parameterized logarithmic image processing method with Laplacian of Gaussian filtering for lung nodule enhancement in chest radiographs

Sheng Chen et al. Med Biol Eng Comput. 2016 Nov.

Abstract

The enhancement of lung nodules in chest radiographs (CXRs) plays an important role in the manual as well as computer-aided detection (CADe) lung cancer. In this paper, we proposed a parameterized logarithmic image processing (PLIP) method combined with the Laplacian of a Gaussian (LoG) filter to enhance lung nodules in CXRs. We first applied several LoG filters with varying parameters to an original CXR to enhance the nodule-like structures as well as the edges in the image. We then applied the PLIP model, which can enhance lung nodule images with high contrast and was beneficial in extracting effective features for nodule detection in the CADe scheme. Our method combined the advantages of both the PLIP algorithm and the LoG algorithm, which can enhance lung nodules in chest radiographs with high contrast. To test our nodule enhancement method, we tested a CADe scheme, with a relatively high performance in nodule detection, using a publically available database containing 140 nodules in 140 CXRs enhanced through our nodule enhancement method. The CADe scheme attained a sensitivity of 81 and 70 % with an average of 5.0 frame rate (FP) and 2.0 FP, respectively, in a leave-one-out cross-validation test. By contrast, the CADe scheme based on the original image recorded a sensitivity of 77 and 63 % at 5.0 FP and 2.0 FP, respectively. We introduced the measurement of enhancement by entropy evaluation to objectively assess our method. Experimental results show that the proposed method obtains an effective enhancement of lung nodules in CXRs for both radiologists and CADe schemes.

Keywords: Chest radiographs (CXRs); Image enhancement; Laplacian of Gaussian (LoG); Lung nodules; Parameterized logarithmic image processing (PLIP).

PubMed Disclaimer

Similar articles

Cited by

References

    1. Med Biol Eng Comput. 2010 Jan;48(1):49-58 - PubMed
    1. IEEE Trans Image Process. 1995;4(6):845-9 - PubMed
    1. IEEE Trans Image Process. 1995;4(4):506-12 - PubMed
    1. Med Biol Eng Comput. 2013 Apr;51(4):459-66 - PubMed
    1. Radiology. 1992 Jan;182(1):115-22 - PubMed

LinkOut - more resources