Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2016 Apr 25;80(5):1163-70.
doi: 10.1253/circj.CJ-16-0106. Epub 2016 Mar 25.

Left Ventricular Global Strain for Estimating Relaxation and Filling Pressure - A Multicenter Study

Affiliations
Free article
Comparative Study

Left Ventricular Global Strain for Estimating Relaxation and Filling Pressure - A Multicenter Study

Taichi Hayashi et al. Circ J. .
Free article

Abstract

Background: Speckle-tracking echocardiography (STE)-derived parameters may have better correlation with left ventricular (LV) relaxation and filling pressure than tissue Doppler-derived parameters. However, it has not been elucidated which parameter - strain or strain rate - and which direction of myocardial deformation - longitudinal or circumferential - is the most useful marker of LV relaxation and filling pressure.

Methods and results: We conducted a prospective multicenter study and compared the correlation of tissue Doppler- and STE-derived parameters with the time constant of LV pressure decay (τ) and LV mean diastolic pressure (MDP) in 77 patients. The correlation of early-diastolic mitral annular velocity (e´) with τ was weak (r=-0.32, P<0.01), and that of peak longitudinal strain (LS) was the strongest (r=-0.45, P<0.001) among the STE-derived parameters. There was a modest correlation between LVMDP and the ratio of early-diastolic inflow velocity (E) to e´ (E/e´) (r=0.50, P<0.001). In contrast, the ratio of E to LS (E/LS) correlated strongly with LVMDP (r=0.70, P<0.001). The correlation of E/LS with LVMDP was significantly better than that for E/e´ (P<0.01). Receiver-operating characteristic analysis showed that E/LS had the largest area under the curve for distinguishing elevated LVMDP (E/LS 0.86, E/e´ 0.74, E/A 0.67).

Conclusions: STE-derived longitudinal parameters correlated well with LV relaxation and filling pressure. In particular, E/LS could be more accurate than E/e´ for estimating LV filling pressure. (Circ J 2016; 80: 1163-1170).

PubMed Disclaimer