Safety enhancement in adult body computed tomography scanning: comparison of iodixanol versus iohexol
- PMID: 27026845
- PMCID: PMC4766145
- DOI: 10.1186/s40064-016-1754-z
Safety enhancement in adult body computed tomography scanning: comparison of iodixanol versus iohexol
Abstract
Background: The aim of this study was to compare the safety and intra-individual contrast enhancement of low-osmolar monomeric iohexol and the iso-osmolar dimeric iodixanol in body computed tomography (CT) scanning.
Methods: In this single center, double-blind, prospective study, a total of 2000 consecutive patients undergoing adult body CT scanning were prospectively enrolled, with 1000 patients assigned to iodixanol and 1000 patients assigned to iohexol. In both groups, the contrast medium was injected at the rate of 3.5 ml/s. Subjective assessment of image quality for each image was determined using a 3-grading scale by three reviewers. Patients were monitored with questioning and vital signs before injection, immediately after injection, and at 24 and 48 h. Extensive laboratory evaluation also was performed.
Results: Laboratory results showed no significant difference across groups. There were also no detectable differences in image quality between the two contrast groups in this study. The total adverse reactions occurred in less than 1 % of individuals receiving iodixanol comparing to 2.5 % in iohexol group (P < 0.05). Among them, only 0.7 % patients injecting iodixanol suffered immediate events, comparing to 2 % patients in iohexol group. In all, 0.2 % patients with iodixanol and 0.5 % with iohexol had late allergic reaction. Further, No deaths occurred in any of the two groups.
Conclusions: The iso-osmolar iodixanol provides image quality compared with that of iohexol, with lower incidence of adverse events.
Keywords: Adverse events; Body computed tomography (CT); Iodixanol; Iohexol.
Similar articles
-
Coronary computed tomographic angiography in coronary artery bypass grafts: comparison between low-concentration Iodixanol 270 and Iohexol 350.J Comput Assist Tomogr. 2015 Jan-Feb;39(1):112-8. doi: 10.1097/RCT.0000000000000162. J Comput Assist Tomogr. 2015. PMID: 25299799 Clinical Trial.
-
A randomized comparison of iodixanol and iohexol in adult body computed tomography scanning.Acad Radiol. 1996 Sep;3 Suppl 3:S500-6. doi: 10.1016/s1076-6332(05)80366-6. Acad Radiol. 1996. PMID: 8883528 Clinical Trial.
-
Optimal contrast agents for vascular imaging on computed tomography: iodixanol versus iohexol.Acad Radiol. 2005 May;12(5):576-84. doi: 10.1016/j.acra.2005.01.015. Acad Radiol. 2005. PMID: 15866130
-
A meta-analysis of the risk of total cardiovascular events of isosmolar iodixanol compared with low-osmolar contrast media.J Cardiol. 2014 Apr;63(4):260-8. doi: 10.1016/j.jjcc.2013.11.021. Epub 2014 Jan 4. J Cardiol. 2014. PMID: 24397991 Review.
-
The relative renal safety of iodixanol compared with low-osmolar contrast media: a meta-analysis of randomized controlled trials.JACC Cardiovasc Interv. 2009 Jul;2(7):645-54. doi: 10.1016/j.jcin.2009.05.002. JACC Cardiovasc Interv. 2009. PMID: 19628188 Review.
Cited by
-
Prevention of post-contrast kidney injury in patients with cancer.Drugs Context. 2024 Mar 14;13:2023-11-2. doi: 10.7573/dic.2023-11-2. eCollection 2024. Drugs Context. 2024. PMID: 38510312 Free PMC article. Review.
-
Efficacy and Safety of Iodixanol in Computed Coronary Tomographic Angiography and Cardiac Catheterization.J Cardiovasc Dev Dis. 2023 Oct 31;10(11):449. doi: 10.3390/jcdd10110449. J Cardiovasc Dev Dis. 2023. PMID: 37998507 Free PMC article. Review.
-
Contrast Kinetics in CT Coronary Angiography.Indian J Radiol Imaging. 2024 Nov 19;35(2):234-241. doi: 10.1055/s-0044-1792038. eCollection 2025 Apr. Indian J Radiol Imaging. 2024. PMID: 40297112 Free PMC article. Review.
References
LinkOut - more resources
Full Text Sources
Other Literature Sources