Psychometric properties of the Chinese version of the Self-Efficacy for Appropriate Medication Use Scale in patients with stroke
- PMID: 27042023
- PMCID: PMC4798205
- DOI: 10.2147/PPA.S101844
Psychometric properties of the Chinese version of the Self-Efficacy for Appropriate Medication Use Scale in patients with stroke
Abstract
Background: It has been reported that stroke has a higher incidence and mortality rate in the People's Republic of China compared to the global average. These conditions can be managed by proper medication use, but ensuring medication adherence is challenging.
Objective: To translate the Self-Efficacy for Appropriate Medication Use Scale into Chinese and test its validity and reliability in patients with stroke.
Methods: Instrument performances were measured from January 15, 2015 to April 28, 2015 on a convenience sample of 400 patients with stroke recruited at four neurology departments of the First Affiliated Hospital of Zhengzhou University. Questionnaires included the Chinese versions of the Self-Efficacy for Appropriate Medication Use Scale (C-SEAMS) and the General Self-Efficacy Scale (C-GSE). Construct validity, convergent validity, internal consistency, and test-retest reliability were measured.
Results: Item analysis showed that item-to-total correlations were in the range of 0.362-0.672. Exploratory factor analysis revealed two factors (which accounted for 60.862% of total variance), with factor loading ranging from 0.534 to 0.756. Confirmatory factor analysis was performed to support the results, with an acceptable fit (χ (2)=73.716; df=64; P<0.01; goodness-of-fit index =0.902; adjusted goodness-of-fit index =0.897; comparative fit index =0.865; root-mean-square error of approximation =0.058). The convergent validity of the C-SEAMS correlated well with the validated measure of the C-GSE in measuring self-efficacy (r=0.531, P<0.01). Good internal consistency (Cronbach's alpha ranged from 0.826 to 0.915) and test-retest reliability (Pearson's correlation coefficient r=0.642, P<0.01) were found.
Conclusion: The C-SEAMS is a brief and psychometrically sound measure for evaluating self-efficacy for medication adherence in the Chinese population with stroke.
Keywords: medication management; psychometric testing; self-efficacy; stroke; survey designs.
Similar articles
-
The psychometric properties of Chinese version of SCI Exercise Self-Efficacy Scale in patients with stroke.Patient Prefer Adherence. 2016 Jul 18;10:1235-41. doi: 10.2147/PPA.S106938. eCollection 2016. Patient Prefer Adherence. 2016. PMID: 27499614 Free PMC article.
-
Reliability and validity of the Chinese version of the eight-item Morisky Medication Adherence Scale in Chinese patients with systemic lupus erythematosus.Clin Rheumatol. 2022 Sep;41(9):2713-2720. doi: 10.1007/s10067-022-06195-y. Epub 2022 May 10. Clin Rheumatol. 2022. PMID: 35536414
-
Cross-cultural adaptation and psychometric properties of the Chinese version of the postpartum depression literacy scale.Front Psychol. 2022 Aug 9;13:966770. doi: 10.3389/fpsyg.2022.966770. eCollection 2022. Front Psychol. 2022. PMID: 36017447 Free PMC article.
-
Validation and psychometric properties of the self-efficacy for Appropriate Medication Use Scale in elderly Chinese patients.Int J Clin Pharm. 2021 Jun;43(3):586-594. doi: 10.1007/s11096-020-01167-1. Epub 2020 Oct 12. Int J Clin Pharm. 2021. PMID: 33044679
-
Self-efficacy for medication management: a systematic review of instruments.Patient Prefer Adherence. 2018 Jul 20;12:1279-1287. doi: 10.2147/PPA.S165749. eCollection 2018. Patient Prefer Adherence. 2018. PMID: 30050290 Free PMC article. Review.
Cited by
-
A community-based nurse-led medication self-management intervention in the improvement of medication adherence in older patients with multimorbidity: protocol for a randomised controlled trial.BMC Geriatr. 2021 Mar 2;21(1):152. doi: 10.1186/s12877-021-02097-x. BMC Geriatr. 2021. PMID: 33653300 Free PMC article.
-
Measures of self-regulation used in adult rehabilitation populations: A systematic review and content screening.Clin Rehabil. 2022 Aug;36(8):1120-1138. doi: 10.1177/02692155221091510. Epub 2022 Apr 27. Clin Rehabil. 2022. PMID: 35473388 Free PMC article.
-
Validation of an Arabic Version of the Adherence to Refills and Medications Scale (ARMS).Healthcare (Basel). 2021 Oct 24;9(11):1430. doi: 10.3390/healthcare9111430. Healthcare (Basel). 2021. PMID: 34828477 Free PMC article.
-
Social support and medication adherence among adult myasthenia gravis patients in China: the mediating role of mental health and self-efficacy.Orphanet J Rare Dis. 2024 Apr 4;19(1):143. doi: 10.1186/s13023-024-03145-6. Orphanet J Rare Dis. 2024. PMID: 38576038 Free PMC article.
-
Prescribers' perceptions of medication discontinuation: survey instrument development and validation.Am J Manag Care. 2016 Nov;22(11):747-754. Am J Manag Care. 2016. PMID: 27870547 Free PMC article.
References
-
- Zhao JJ, He GQ, Gong SY, He L. Status and costs of primary prevention for ischemic stroke in China. J Clin Neurosci. 2013;20(10):1427–1432. - PubMed
-
- Wu X, Zou S, Zhu B, Shi J. The hospital costs of stroke patients in Chinese island populations: an 11-year tendency analysis. J Stroke Cerebrovasc Dis. 2015;24(5):988–992. - PubMed
-
- Sun XG, Wang T, Zhang N, Yang QD, Liu YH. Incidence and survival of lacunar infarction in a southern Chinese population: a 7-year prospective study. Brain Inj. 2015;29(6):739–744. - PubMed
-
- Ji R, Liu G, Shen H, et al. Persistence of secondary prevention medications after acute ischemic stroke or transient ischemic attack in Chinese population: data from China National Stroke Registry. Neurol Res. 2013;35(1):29–36. - PubMed
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous