Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comment
. 2016 Jun;87(3):257-61.
doi: 10.3109/17453674.2016.1162898. Epub 2016 Apr 4.

Substantially higher prevalence of postoperative peri-prosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem

Affiliations
Comment

Substantially higher prevalence of postoperative peri-prosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem

Sebastian Mukka et al. Acta Orthop. 2016 Jun.

Abstract

Background and purpose - Recent studies have demonstrated a high incidence of postoperative periprosthetic femoral fracture (PPF) in elderly patients treated with 2 commonly used cemented, polished tapered stems. We compared the prevalence and incidence rate of PPF in a consecutive cohort of octagenerians with femoral neck fractures (FNFs) treated with either a collarless, polished tapered (CPT) stem or an anatomic matte stem (Lubinus SP2). Patients and methods - In a multicenter, prospective cohort study, we included 979 hips in patients aged 80 years and above (72% females, median age 86 (80-102) years) with a femoral neck fracture as indication for surgery. 69% of the patients were classified as ASA class 3 or 4. Hip-related complications and repeat surgery were assessed at a median follow-up of 20 (0-24) months postoperatively. Results - 22 hips (2.2%) sustained a PPF at a median of 7 (0-22) months postoperatively; 14 (64%) were Vancouver B2 fractures. 7 of the 22 surgically treated fractures required revision surgery, mainly due to deep infection. The cumulative incidence of PPFs was 3.8% in the CPT group, as compared with 0.2% in the SP2 group (p < 0.001). The risk ratio (RR) was 16 (95% CI: 2-120) using the SP2 group as denominator. Interpretation - The CPT stem was associated with a higher risk of PPF than the SP2 stem. We suggest that the tapered CPT stem should not be used for the treatment of femoral neck fractures in patients over 80 years.

PubMed Disclaimer

Comment on

References

    1. Bishop N E, Burton A, Maheson M, Morlock M M.. Biomechanics of short hip endoprostheses–the risk of bone failure increases with decreasing implant size. Clin Biomech (Bristol, Avon) 2010; 25 (7): 666–74. - PubMed
    1. Brady O H, Garbuz D S, Masri B A, Duncan C P.. The reliability and validity of the Vancouver classification of femoral fractures after hip replacement. J Arthroplasty 2000; 15 (1): 59–62. - PubMed
    1. Brodén C, Mukka S, Muren O, Eisler T, Boden H, Stark A, et al. High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem. Acta Orthop 2015; 86 (2): 169–74. - PMC - PubMed
    1. Burston B J, Barnett A J, Amirfeyz R, Yates P J, Bannister G C.. Clinical and radiological results of the collarless polished tapered stem at 15 years follow-up. J Bone Joint Surg Br 2012; 94 (7): 889–94. - PubMed
    1. Chammout GK, Mukka SS, Carlsson T, Neander GF, Stark AW, Skoldenberg OG.. Total hip replacement versus open reduction and internal fixation of displaced femoral neck fractures: a randomized long-term follow-up study. J Bone Joint Surg Am 2012. Nov 7;94(21):1921–8. - PubMed