Validation of a New Placebo Interferential Current Method: A New Placebo Method of Electrostimulation
- PMID: 27048345
- DOI: 10.1093/pm/pnw039
Validation of a New Placebo Interferential Current Method: A New Placebo Method of Electrostimulation
Abstract
Objective: The present study aimed to investigate if a new placebo device for interferential current (IFC) that delivers current during only the first 40 seconds of stimulation is effective at promoting adequate subject blinding.
Methods: Seventy-five subjects were recruited and enrolled into three groups: active IFC, inactive placebo, and new placebo. Pressure pain threshold (PPT), cutaneous sensory threshold (CST), and pain intensity were measured before and after the intervention. After the final assessment, the subjects and the investigator who applied the current were asked about the type of stimulation administered.
Results: None of the placebo forms studied resulted in significant changes to PPT, CST, or pain intensity. The subjects stimulated with active IFC at high intensities (> 17 mA) of stimulation showed higher PPT and CST and lower pain intensity than subjects stimulated at low intensities ( p < 0.03). The new placebo method blinded the investigator in 100% of cases of IFC and 60% of subjects stimulated, whereas for inactive placebo, the investigator was blinded at a rate of 0% and 34% of subjects.
Conclusion: The new method of placebo IFC was effective for blinding of research investigators and most of the active IFC-treated subjects, promoting an appropriate placebo method.
Keywords: Cutaneous Sensory Threshold; Electric Stimulation Therapy; Interferential Current; Pain Measurement; Placebo Effect.
© 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Similar articles
-
Interferential current intensity influences the hypoalgesic response in healthy subjects under mechanically-induced pain: A randomized controlled trial.Physiother Theory Pract. 2023 Oct 3;39(10):2087-2098. doi: 10.1080/09593985.2022.2068095. Epub 2022 May 3. Physiother Theory Pract. 2023. PMID: 35505631 Clinical Trial.
-
A new transient sham TENS device allows for investigator blinding while delivering a true placebo treatment.J Pain. 2010 Mar;11(3):230-8. doi: 10.1016/j.jpain.2009.07.007. Epub 2009 Nov 27. J Pain. 2010. PMID: 19945354 Free PMC article. Clinical Trial.
-
Effects of carrier frequency of interferential current on pressure pain threshold and sensory comfort in humans.Arch Phys Med Rehabil. 2013 Jan;94(1):95-102. doi: 10.1016/j.apmr.2012.08.204. Epub 2012 Aug 23. Arch Phys Med Rehabil. 2013. PMID: 22922327 Clinical Trial.
-
Analgesic Effects of Interferential Current Therapy: A Narrative Review.Medicina (Kaunas). 2022 Jan 17;58(1):141. doi: 10.3390/medicina58010141. Medicina (Kaunas). 2022. PMID: 35056448 Free PMC article. Review.
-
Interferential current therapy.Br J Sports Med. 1990 Jun;24(2):87-92. doi: 10.1136/bjsm.24.2.87. Br J Sports Med. 1990. PMID: 1702337 Free PMC article. Review. No abstract available.
Cited by
-
Comparing the effects of transcranial alternating current and temporal interference (tTIS) electric stimulation through whole-brain mapping of c-Fos immunoreactivity.Front Neuroanat. 2023 Mar 13;17:1128193. doi: 10.3389/fnana.2023.1128193. eCollection 2023. Front Neuroanat. 2023. PMID: 36992795 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources