Abstract
Background: Body composition is an important component of health related fitness. Near-infrared spectroscopy (NIRS) is a non-invasive, simple and rapid method of assessing body fat percentage. However, it is unknown whether NIRS can accurately estimate FFM in community-dwelling frail elderly.
Objectives: This study aimed to compare NIRS with bioelectrical impedance analysis (BIA) in FFM measurement.
Design: Cross-sectional study.
Setting: Shizuoka, Japan.
Participants: The study population comprised 53 community-dwelling frail elderly (15 men, 38 women; mean age 84.8±6.4 years; body mass index 19.7±3.5 kg/m2).
Measurement: FFM and percentage fat mass (%FM) were estimated using a NIRS device at two sites (biceps and calf) and compared to body composition measured by BIA. Simple linear regression and Bland-Altman analyses were used to determine agreement between the methods.
Results: FFM determined by BIA highly correlated with that determined by NIRS at both the biceps and calf (r=0.92 for both; p<0.001). The correlation coefficients for %FM estimated by NIRS were slightly lower (r=0.70 for biceps; r=0.66 for calf). In NIRS assessments, systematic biases were found for %FM but not for FFM.
Conclusion: NIRS has significant potential for body composition analysis. Further comparative and longitudinal studies need to be conducted using an agreed reference analysis method to find a simple and more suitable method that can be applied among the community-dwelling frail elderly.
Similar articles
-
Estimation of body composition depends on applied device in patients undergoing major abdominal surgery.Nutr Clin Pract. 2015 Apr;30(2):249-56. doi: 10.1177/0884533614542614. Epub 2014 Aug 8. Nutr Clin Pract. 2015. PMID: 25107953
-
Assessment of body composition in subjects with metabolic syndrome comparing single-frequency bioelectrical impedance analysis and bioelectrical spectroscopy.Metab Syndr Relat Disord. 2015 Mar;13(2):91-8. doi: 10.1089/met.2014.0130. Epub 2014 Dec 29. Metab Syndr Relat Disord. 2015. PMID: 25545543 Clinical Trial.
-
Body composition analysis by leg-to-leg bioelectrical impedance and dual-energy X-ray absorptiometry in non-obese and obese individuals.Diabetes Obes Metab. 2008 Nov;10(11):1012-8. doi: 10.1111/j.1463-1326.2008.00851.x. Epub 2008 Apr 22. Diabetes Obes Metab. 2008. PMID: 18435776
-
Specific bioelectrical impedance vector reference values for assessing body composition in the Italian elderly.Exp Gerontol. 2014 Feb;50:52-6. doi: 10.1016/j.exger.2013.11.016. Epub 2013 Dec 3. Exp Gerontol. 2014. PMID: 24316033
-
Foot-to-foot bioelectrical impedance analysis: a valuable tool for the measurement of body composition in children.Int J Obes Relat Metab Disord. 2001 Feb;25(2):273-8. doi: 10.1038/sj.ijo.0801531. Int J Obes Relat Metab Disord. 2001. PMID: 11410831