Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Apr-Jun;10(2):198-201.
doi: 10.4103/1658-354X.168825.

Cadaveric feasibility study on the use of ultrasound contrast to assess spread of injectate in the serratus anterior muscle plane

Affiliations

Cadaveric feasibility study on the use of ultrasound contrast to assess spread of injectate in the serratus anterior muscle plane

V Daga et al. Saudi J Anaesth. 2016 Apr-Jun.

Abstract

Background: The Serratus anterior muscle plane (SAP) block has recently been described for the purpose of perioperative pain management following cases of trauma and breast surgery. It might prove a safer alternative to the other regional thoracic paravertebral and central neuraxial blockade techniques. There are no descriptive cadaveric studies in the pre-existing literature to delineate the anatomical plane for this novel technique. The main objectives for our study were to examine the location of the Serratus anterior muscle belly, assess the efficacy of achieving adequate delineation of the muscle plane utilising ultrasound imaging with agitated water as the contrast agent, and finally, to observe the extent of the cepahlo-caudal spread of the injectate in the SAP.

Materials and methods: Seven cadavers were studied. 20 mls of saline was injected into posterior axillary line (PAL) at the level of the 4-5(th) rib under ultrasound guidance. This was followed by injection of 10 mls of water with air (8 mls water and 2 mls of air). The presence of hyperechoic air bubbles in the fluid distended SAP (hypoechoic) area demonstrated the spread of water and air.

Results: In 36% of cadavers, fully formed Serratus Anterior muscle belly was identified at the midaxillary line (MAL), 14% in PAL, and remaining 50% between PAL and MAL. The lower most limit of air-water spread was identified at the subcostal margin. Cephalad spread of contrast was noted in 2(nd) intercostal space ICS (7%), 3(rd) ICS (71%), and 4(th) ICS (22%).

Conclusion: This study describes that the serratus anterior muscle is well-formed near the PAL and the injectate spread can be determined with the help of agitated water contrast on ultrasound. Furthermore, there was variability in the cephalad spread of the injectate.

Keywords: Cadaver; serratus anterior plane; ultrasound.

PubMed Disclaimer

Figures

Figure 1
Figure 1
(a) Ultrasound image of incomplete serratus muscle belly in anterior axillary line (b) Ultrasound image of complete belly formation in posterior axillary line (c) Ultrasound image of in-plane view of needle and hypoechoic fluid in-plane (d) Ultrasound image of hyperechoic air bubbles in-plane

References

    1. Tran TM, Ivanusic JJ, Hebbard P, Barrington MJ. Determination of spread of injectate after ultrasound-guided transversus abdominis plane block: A cadaveric study. Br J Anaesth. 2009;102:123–7. - PubMed
    1. Milan Z, Tabor D, McConnell P, Pickering J, Kocarev M, du Feu F, et al. Three different approaches to transversus abdominis planeblock: A cadaveric study. Med Glas (Zenica) 2011;8:181–4. - PubMed
    1. Ishiguro S, Yokochi A, Yoshioka K, Asano N, Deguchi A, Iwasaki Y, et al. Technical communication: Anatomy and clinical implications of ultrasound-guided selective femoral nerve block. Anesth Analg. 2012;115:1467–70. - PubMed
    1. de Jong N, Ten Cate FJ. New ultrasound contrast agents and technological innovations. Ultrasonics. 1996;34:587–90. - PubMed
    1. Kunhabdulla NP, Agarwal A, Gaur A, Gautam SK, Gupta R, Agarwal A. Serratus anterior plane block for multiple rib fractures. Pain Physician. 2014;17:E553–5. - PubMed