Early echocardiographic predictor of heart failure in cerebral arteriovenous malformations
- PMID: 27056343
- DOI: 10.1017/S1047951116000305
Early echocardiographic predictor of heart failure in cerebral arteriovenous malformations
Abstract
Neonatal congestive heart failure in cerebral arteriovenous malformations carries a high risk of mortality. Severe heart failure leading to end-organ dysfunction may be a contraindication to early intervention. Although echocardiographic markers of haemodynamic instability exist, an objective echocardiographic predictor of severe heart failure is not available. We present a ratio of antegrade to retrograde flow in the aortic arch that objectively identifies those at the highest risk of mortality. This measurement can be easily obtained and has prognostic value at presentation, before clinical deterioration. Outcomes remain poor even when early intervention is offered, which may reflect irreversible neurological abnormalities.
Keywords: Arteriovenous malformation; congestive heart failure; prognostic marker.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical