Reducing contrast medium volume and tube voltage in CT angiography of the pulmonary artery
- PMID: 27059387
- DOI: 10.1016/j.crad.2016.03.005
Reducing contrast medium volume and tube voltage in CT angiography of the pulmonary artery
Abstract
Aim: To evaluate image quality after contrast medium (CM) and tube voltage reduction in computed tomography angiography (CTA) of the pulmonary artery.
Materials and methods: Thirty-three patients referred for CTA of the pulmonary artery for suspected pulmonary embolism were included. Patients were randomly assigned to Protocol I (100 ml of 350 mg iodine/ml iodinated CM; n=16) or Protocol II (50 ml of 350 mg iodine/ml iodinated CM; n=17). Dual-energy CT (80 kV and 140 kV) was performed in all patients. An averaged weighted series equivalent to a 120 kV image acquisition was reconstructed. The mean attenuation value of CM was measured at eight positions in the pulmonary trunk and pulmonary arteries. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Qualitative assessment of the vascular enhancement was performed independently by two experienced radiologists using a three-point scale. Mean attenuation values, image noise, CNR, and SNR of images with 50 ml CM and images with 100 ml CM were compared and mean attenuation values, image noise, CNR, and SNR in 80 kV images and 120 kV images were compared. For qualitative analysis, interobserver variability was analysed using Cohen's kappa statistics.
Results: The mean attenuation values in Protocol I and Protocol II were not significantly different at 80 kV (634.6±168.3 versus 537.9±146.7 HU; p=0.088) and 120 kV (482.8±127.7 versus 410.4±106.0 HU; p=0.085). The mean attenuation value at 80 kV was significantly higher than the mean attenuation value at 120 kV in Protocols I and II (p<0.001). The CNR and SNR were higher at 120 kV than at 80 kV in both protocols (p=0.000-0.019); however, there were no significant differences in the CNR and SNR between both protocols (p=0.600-0.952). Qualitative (subjective) analysis showed no statistical significant difference between Protocols I and II (p=0.524-1.000).
Conclusion: Low tube voltage (80 kV) CTA using 50 ml CM is not inferior to CTA at 120 kV using 100 ml CM.
Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
Iterative reconstructed ultra high pitch CT pulmonary angiography with cardiac bowtie-shaped filter in the acute setting: effect on dose and image quality.Eur J Radiol. 2013 Sep;82(9):1571-6. doi: 10.1016/j.ejrad.2013.04.043. Epub 2013 Jun 15. Eur J Radiol. 2013. PMID: 23777744 Clinical Trial.
-
Diagnosis of Pulmonary Artery Embolism: Comparison of Single-Source CT and 3rd Generation Dual-Source CT using a Dual-Energy Protocol Regarding Image Quality and Radiation Dose.Rofo. 2017 Jun;189(6):527-536. doi: 10.1055/s-0043-103089. Epub 2017 Apr 26. Rofo. 2017. PMID: 28445908 English.
-
Radiation and contrast agent doses reductions by using 80-kV tube voltage in coronary computed tomographic angiography: a comparative study.Eur J Radiol. 2014 Feb;83(2):309-14. doi: 10.1016/j.ejrad.2013.06.032. Epub 2013 Nov 15. Eur J Radiol. 2014. PMID: 24315475 Clinical Trial.
-
Did low tube voltage CT combined with low contrast media burden protocols accomplish the goal of "double low" for patients? An overview of applications in vessels and abdominal parenchymal organs over the past 5 years.Int J Clin Pract. 2016 Sep;70 Suppl 9B:B5-B15. doi: 10.1111/ijcp.12861. Int J Clin Pract. 2016. PMID: 27577514 Review.
-
Low radiation dose in computed tomography: the role of iodine.Br J Radiol. 2017 Aug;90(1076):20170079. doi: 10.1259/bjr.20170079. Epub 2017 May 4. Br J Radiol. 2017. PMID: 28471242 Free PMC article. Review.
Cited by
-
Artificial Intelligence-Based Prediction of Contrast Medium Doses for Computed Tomography Angiography Using Optimized Clinical Parameter Sets.Methods Inf Med. 2024 May;63(1-02):11-20. doi: 10.1055/s-0044-1778694. Epub 2024 Jan 23. Methods Inf Med. 2024. PMID: 38262476 Free PMC article.
-
Optimizing low contrast volume thoracic CT angiography: From the basics to the advanced.J Clin Imaging Sci. 2022 Jul 29;12:41. doi: 10.25259/JCIS_51_2022. eCollection 2022. J Clin Imaging Sci. 2022. PMID: 36128360 Free PMC article.
-
Tailoring protocols for chest CT applications: when and how?Diagn Interv Radiol. 2017 Nov-Dec;23(6):420-427. doi: 10.5152/dir.2017.16615. Diagn Interv Radiol. 2017. PMID: 29097345 Free PMC article. Review.
-
Extent of simultaneous radiation dose and iodine reduction at stable image quality in computed tomography of the chest: A systematic approach using automated tube voltage adaption and iterative reconstructions.Medicine (Baltimore). 2018 Apr;97(15):e0388. doi: 10.1097/MD.0000000000010388. Medicine (Baltimore). 2018. PMID: 29642199 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical