Traditional gamma cameras are preferred

Affiliations
Review

Traditional gamma cameras are preferred

E Gordon DePuey. J Nucl Cardiol. 2016 Aug.

Abstract

Although the new solid-state dedicated cardiac cameras provide excellent spatial and energy resolution and allow for markedly reduced SPECT acquisition times and/or injected radiopharmaceutical activity, they have some distinct disadvantages compared to traditional sodium iodide SPECT cameras. They are expensive. Attenuation correction is not available. Cardio-focused collimation, advantageous to increase depth-dependent resolution and myocardial count density, accentuates diaphragmatic attenuation and scatter from subdiaphragmatic structures. Although supplemental prone imaging is therefore routinely advised, many patients cannot tolerate it. Moreover, very large patients cannot be accommodated in the solid-state camera gantries. Since data are acquired simultaneously with an arc of solid-state detectors around the chest, no temporally dependent "rotating" projection images are obtained. Therefore, patient motion can be neither detected nor corrected. In contrast, traditional sodium iodide SPECT cameras provide rotating projection images to allow technologists and physicians to detect and correct patient motion and to accurately detect the position of soft tissue attenuators and to anticipate associated artifacts. Very large patients are easily accommodated. Low-dose x-ray attenuation correction is widely available. Also, relatively inexpensive low-count density software is provided by many vendors, allowing shorter SPECT acquisition times and reduced injected activity approaching that achievable with solid-state cameras.

Keywords: SPECT; attenuation correction; cadmium-zinc-telluride; sodium iodide; solid-state cameras.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. J Nucl Cardiol. 2009 May-Jun;16(3):335-8 - PubMed
    1. J Nucl Cardiol. 2012 Oct;19(5):931-44 - PubMed
    1. J Nucl Cardiol. 2017 Apr;24(2):596-604 - PubMed
    1. J Nucl Cardiol. 2014 Dec;21(6):1260-5 - PubMed
    1. J Nucl Cardiol. 2010 Aug;17(4):709-18 - PubMed

MeSH terms

LinkOut - more resources