Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Jun;10(2):145-50.
doi: 10.1007/s11701-016-0587-7. Epub 2016 Apr 12.

Accuracy of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis in the pediatric population

Affiliations

Accuracy of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis in the pediatric population

Jeremy J Macke et al. J Robot Surg. 2016 Jun.

Abstract

This is a retrospective review of pedicle screw placement in adolescent idiopathic scoliosis (AIS) patients under 18 years of age who underwent robot-assisted corrective surgery. Our primary objective was to characterize the accuracy of pedicle screw placement with evaluation by computed tomography (CT) after robot-assisted surgery in AIS patients. Screw malposition is the most frequent complication of pedicle screw placement and is more frequent in AIS. Given the potential for serious complications, the need for improved accuracy of screw placement has spurred multiple innovations including robot-assisted guidance devices. No studies to date have evaluated this robot-assisted technique using CT exclusively within the AIS population. Fifty patients were included in the study. All operative procedures were performed at a single institution by a single pediatric orthopedic surgeon. We evaluated the grade of screw breach, the direction of screw breach, and the positioning of the patient for preoperative scan (supine versus prone). Of 662 screws evaluated, 48 screws (7.2 %) demonstrated a breach of greater than 2 mm. With preoperative prone position CT scanning, only 2.4 % of screws were found to have this degree of breach. Medial malposition was found in 3 % of screws, a rate which decreased to 0 % with preoperative prone position scanning. Based on our results, we conclude that the proper use of image-guided robot-assisted surgery can improve the accuracy and safety of thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis. This is the first study to evaluate the accuracy of pedicle screw placement using CT assessment in robot-assisted surgical correction of patients with AIS. In our study, the robot-assisted screw misplacement rate was lower than similarly constructed studies evaluating conventional (non-robot-assisted) procedures. If patients are preoperatively scanned in the prone position, the misplacement rate is further decreased.

Keywords: Adolescent idiopathic scoliosis; Pediatrics; Robotic surgery; Scoliosis; Spinal fusion; Surgical outcomes.

PubMed Disclaimer

References

    1. Eur Spine J. 2014 Feb;23(2):291-7 - PubMed
    1. Spine (Phila Pa 1976). 2005 Jan 15;30(2):222-6 - PubMed
    1. Spine (Phila Pa 1976). 2010 Nov 15;35(24):2109-15 - PubMed
    1. J Robot Surg. 2013 Jun;7(2):177-85 - PubMed
    1. J Med Assoc Thai. 2007 Jan;90(1):96-105 - PubMed

Publication types

LinkOut - more resources