Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Sep;23(14):1486-95.
doi: 10.1177/2047487316645468. Epub 2016 Apr 20.

Are aerobic interval training and continuous training isocaloric in coronary artery disease patients?

Affiliations

Are aerobic interval training and continuous training isocaloric in coronary artery disease patients?

Nele Pattyn et al. Eur J Prev Cardiol. 2016 Sep.

Abstract

Background: Aerobic interval training (IT) seems to be superior to continuous training (CT) in improving exercise capacity (peak oxygen uptake (VO2)) in coronary artery disease (CAD) patients in some, but not in all studies. Based on theoretical calculations, these comparative studies stated that the energy expenditure (EE) of both programmes is similar. To date, the caloricity of both programmes has never been objectively measured. Therefore, our aim was to objectively measure the EE of the IT and CT programmes described in the protocol of the SAINTEX-CAD study (based on Wisloff et al.; ITw and CTw), and the actually performed training intensities in the SAINTEX-CAD study by Conraads et al. (ITc and CTc).

Methods: Following a two-week run-in period with three IT and three CT training sessions, 18 male CAD patients (mean age 62.4 ± 6.1 years) performed four training sessions in random order on the cycle ergometer: an ITw, CTw, ITc and CTc test session. The EE was assessed by indirect calorimetry using gas exchange measurements obtained with the Oxycon mobile.

Results: We found a higher EE for CTc compared to ITc (352 ± 90.8 kcal versus 269 ± 70.7 kcal; p = 0.026), while CTw and ITw seemed to be isocaloric (317 ± 85.2 kcal versus 273 ± 65.3 kcal; p = 0.42). Higher lactate levels were reached after IT sessions (ITw 5.42 ± 1.42 mmol/l, ITc 5.05 ± 1.38 mmol/l) compared to CT sessions (CTw 2.45 ± 1.04 mmol/l, CTc 3.41 ± 1.44 mmol/l) (p < 0.01). Lactate levels increased above baseline levels (1.91 ± 0.34 mmol/l) except for the CTw session.

Conclusion: CTc expended significantly more energy compared to ITc, showing that the programmes used in the SAINTEX-CAD study were not isocaloric. In contrast, isocaloricity was met for CTw and ITw.

Keywords: Isocaloric; Oxycon mobile; aerobic exercise; coronary artery disease; energy expenditure; indirect calorimetry; interval training.

PubMed Disclaimer

Similar articles

Publication types