Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Dec;126(12):2764-2769.
doi: 10.1002/lary.26016. Epub 2016 Apr 23.

Reliability of office-based narrow-band imaging-guided flexible laryngoscopic tissue samplings

Affiliations

Reliability of office-based narrow-band imaging-guided flexible laryngoscopic tissue samplings

Catherine Chang et al. Laryngoscope. 2016 Dec.

Abstract

Objectives/hypothesis: Direct suspension laryngoscopic biopsy performed under general anesthesia is the conventional management for obtaining pathological diagnosis for neoplasms of the larynx, oropharynx, and hypopharynx. Since the development of distal chip laryngoscopy and digital imaging systems, transnasal flexible laryngoscopy tissue sampling has gained popularity as an office-based procedure. Additional assessment with narrow-band imaging (NBI) can help to increase the diagnostic yield. The aim of the study was to evaluate the accuracy, sensitivity, and specificity of a novel diagnostic tool: office-based NBI (OB-NBI) flexible laryngoscopic tissue sampling.

Study design: Retrospective chart review performed in a tertiary referral medical center in Taiwan.

Methods: From January 2010 to February 2013, 90 consecutive patients received OB-NBI biopsies. The accuracies of the OB-NBI biopsies were compared among locations, tumor sizes, head and neck cancer histories, and other factors.

Results: All patients had completed the procedure without life-threatening complications. The overall sensitivity and specificity were 97.2% and 100%, respectively, with a diagnostic accuracy of 98.9%. Accuracy was not affected by tumor size, location, learning curves, or previous head and neck cancer history.

Conclusions: We present an integrated technique that merges the safety and versatility of flexible laryngoscopy with the diagnostic power of NBI to produce a promising method of high accuracy and minimal morbidity.

Level of evidence: 4 Laryngoscope, 126:2764-2769, 2016.

Keywords: Office biopsy; flexible laryngoscopy; narrow-band imaging.

PubMed Disclaimer

Publication types

LinkOut - more resources