Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms
- PMID: 27114447
- DOI: 10.1177/1538574416642872
Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms
Abstract
Objective: Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion.
Methods: Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries.
Results: We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs < 50 cm/s throughout the graft, and Vr > 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication.
Conclusion: Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms.
Keywords: duplex ultrasonography; popliteal aneurysm; stent graft.
© The Author(s) 2016.
Similar articles
-
Duplex ultrasound diagnosis of failing stent grafts placed for occlusive disease.J Vasc Surg. 2014 Dec;60(6):1580-4. doi: 10.1016/j.jvs.2014.08.071. Epub 2014 Sep 22. J Vasc Surg. 2014. PMID: 25256612
-
Duplex Ultrasound for Diagnosis of Failing Stents Placed for Lower Extremity Arterial Occlusive Disease.Ann Vasc Surg. 2020 Feb;63:269-274. doi: 10.1016/j.avsg.2019.08.086. Epub 2019 Oct 15. Ann Vasc Surg. 2020. PMID: 31626930
-
Endovascular exclusion of popliteal artery aneurysms with expanded polytetrafluoroethylene stent-grafts: early results.Vasc Endovascular Surg. 2006 Dec-2007 Jan;40(6):460-6. doi: 10.1177/1538574406294366. Vasc Endovascular Surg. 2006. PMID: 17202092
-
A Systematic Review and Meta-analysis of Endovascular Popliteal Aneurysm Repair Using the Hemobahn/Viabahn Stent-Graft.J Endovasc Ther. 2015 Jun;22(3):330-7. doi: 10.1177/1526602815579252. Epub 2015 Apr 10. J Endovasc Ther. 2015. PMID: 25862366
-
Flow-diverting stents for the treatment of arterial aneurysms.J Vasc Surg. 2012 Sep;56(3):839-46. doi: 10.1016/j.jvs.2012.04.020. Epub 2012 Jul 26. J Vasc Surg. 2012. PMID: 22840737 Review.
Cited by
-
Observational study of endoluminal mural thrombotic apposition in popliteal artery aneurysm stenting and its relationship with stent-graft geometrical features.Front Cardiovasc Med. 2023 Aug 7;10:1176455. doi: 10.3389/fcvm.2023.1176455. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 37608810 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical