Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Jul;32(7):1253-62.
doi: 10.1016/j.arthro.2016.01.010. Epub 2016 Apr 23.

Profile of Current Opinion on Arthroscopic Acromioplasty: A Video Survey Study

Collaborators, Affiliations

Profile of Current Opinion on Arthroscopic Acromioplasty: A Video Survey Study

Danielle Y Ponzio et al. Arthroscopy. 2016 Jul.

Abstract

Purpose: To provide a baseline profile of current opinion on use of arthroscopic acromioplasty and evaluate the consistency of surgical decision making on whether or not to perform acromioplasty across different surgeon practices.

Methods: Twenty-two fellowship-trained orthopaedic shoulder surgeons from the Association of Clinical Elbow and Shoulder Surgeons completed an Internet-based survey on practices associated with acromioplasty, including questions related to 15 arthroscopic videos. Based on video cases, interobserver and intraobserver agreement regarding clinically based decisions related to acromioplasty were assessed.

Results: Acromioplasty was uncommonly performed in isolation among this group and was most commonly performed in conjunction with repair of full-thickness rotator cuff tears. Nineteen of 22 (86%) surgeons favored an arthroscopic approach for acromioplasty. Depth of bony resection was determined most commonly based on clinical judgment and experience (68%). The video portion of the survey revealed slight interobserver agreement for classification of acromion morphology (κ = 0.099), need for acromioplasty (κ = 0.020), and adequacy of decompression (κ = 0.1). In contrast, there was fair intraobserver reliability regarding acromion morphology (κ = 0.370) and decision whether to perform acromioplasty in a given case (κ = 0.348) whereas there was moderate intraobserver reliability in the presence of a reparable rotator cuff tear (κ = 0.507) and assessment of the adequacy of decompression (κ = 0.453).

Conclusions: Although surgeons had similarities regarding principles of acromioplasty, including indications, surgical approach, and technique, there was lack of consensus when surgeons reviewed the video of clinical cases. Although surgeons may have similar goals in terms of treatment of pathology related to subacromial impingement, individual surgeon thresholds for the need and adequacy of decompression are varied and are not standardized.

Level of evidence: Level V, expert opinion.

PubMed Disclaimer

LinkOut - more resources