Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients

Affiliations

Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients

Suyoung Kim et al. Korean J Radiol. 2016 May-Jun.

Abstract

Objective: To estimate and compare radiation exposure and intervention time during lumbar epidural steroid injection (ESI) 1) under different practitioners and methods with continuous fluoroscopic monitoring, and 2) under one practitioner with different methods and monitoring.

Materials and methods: We consecutively recruited 804 patients who underwent lumbar ESI and 759 patients who underwent 922 interventions were included for analysis in this investigation. Three different practitioners (a senior faculty member, junior faculty member, trainee) performed lumbar ESI using different methods (caudal, interlaminar, transforaminal). The senior faculty member performed lumbar ESI under two different methods of fluoroscopic monitoring (continuous [CM] and intermittent monitoring [IM]). The dose area product (DAP) fluoroscopy time, and intervention time during lumbar ESI were compared for 1) ESI methods and practitioners under CM, and 2) ESI methods and monitoring.

Results: With CM, interaction between the effects of the practitioner and the intervention on DAP was significant (p < 0.001), but not fluoroscopy time (p = 0.672) or intervention time (p = 0.852). The significant main effects included the practitioner and intervention on DAP, fluoroscopy time, and intervention time with CM (p < 0.001). DAPs and fluoroscopy time for caudal, interlaminar, and transforaminal ESI were higher with CM than with IM (p < 0.001). Intervention time did not differ between CM and IM.

Conclusion: Radiation exposure is dependent on the practitioners and methods and within the established safety limits during lumbar ESIs under CM. With an experienced practitioner, IM leads to less radiation exposure than CM.

Keywords: Epidural steroid injection; Fluoroscopy; Low back pain; Radiation dosage.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1. Box-and-whisker plot of characteristics [radiation dose (A), fluoroscopy time (B), intervention time (C)] according to different practitioners (senior faculty member, junior faculty member, and trainee) and epidural steroid injection methods (caudal, interlaminar, and transforaminal epidural steroid injections) during continuous monitoring.
Middle lines of boxes show medians, and upper and lower box margins represent upper and lower quartiles, respectively. Ends of vertical lines indicate lowest and highest value, respectively.
Fig. 2
Fig. 2. Box-and-whisker plot of characteristics [radiation dose (A), fluoroscopy time (B), intervention time (C)] according to different monitoring methods (continuous and intermittent fluoroscopy monitoring) and epidural steroid injection methods (caudal, interlaminar, and transforaminal epidural steroid injections) in senior faculty member.
Middle lines of boxes show medians, and upper and lower box margins represent upper and lower quartiles, respectively. Ends of vertical lines indicate lowest and highest value, respectively.

References

    1. White AH, Derby R, Wynne G. Epidural injections for the diagnosis and treatment of low-back pain. Spine (Phila Pa 1976) 1980;5:78–86. - PubMed
    1. Bartynski WS, Grahovac SZ, Rothfus WE. Incorrect needle position during lumbar epidural steroid administration: inaccuracy of loss of air pressure resistance and requirement of fluoroscopy and epidurography during needle insertion. AJNR Am J Neuroradiol. 2005;26:502–505. - PMC - PubMed
    1. Liu SS, Melmed AP, Klos JW, Innis CA. Prospective experience with a 20-gauge Tuohy needle for lumbar epidural steroid injections: is confirmation with fluoroscopy necessary? Reg Anesth Pain Med. 2001;26:143–146. - PubMed
    1. Weil L, Frauwirth NH, Amirdelfan K, Grant D, Rosenberg JA. Fluoroscopic analysis of lumbar epidural contrast spread after lumbar interlaminar injection. Arch Phys Med Rehabil. 2008;89:413–416. - PubMed
    1. Botwin KP, Natalicchio J, Hanna A. Fluoroscopic guided lumbar interlaminar epidural injections: a prospective evaluation of epidurography contrast patterns and anatomical review of the epidural space. Pain Physician. 2004;7:77–80. - PubMed

LinkOut - more resources