. 2017 May;77(5):1749-1761.
doi: 10.1002/mrm.26251. Epub 2016 May 2.

EPI Nyquist ghost and geometric distortion correction by two-frame phase labeling

Affiliations
Free article

EPI Nyquist ghost and geometric distortion correction by two-frame phase labeling

Victor B Xie et al. Magn Reson Med. 2017 May.
Free article

Abstract

Purpose: To develop a new Nyquist ghost and geometric distortion correction method in echo planar imaging (EPI) using parallel imaging.

Methods: Two frames of EPI data are acquired with normal and phase-labeled sequence. The phase label is applied by modifying the PE prephase gradient to shift the central echo by one echo spacing. GRAPPA weights are trained from both frames and used to reconstruct images from positive or negative echoes in each frame to remove Nyquist ghost. Geometric distortion is then corrected by the B0 field map generated from the phase difference between positive and negative echo images. Phantom and in vivo experiments at 7 Tesla (T) and 3T were performed to evaluate the proposed method.

Results: Nyquist ghost was greatly reduced in all images even under oblique imaging and poor eddy current conditions, yielding significant improvements over the existing reference scan and image entropy minimization based methods. Image geometries were fully restored after distortion correction. Phantom results indicated that the signal-to-noise ratio efficiency was largely preserved while fMRI results showed no apparent degradation of temporal resolution.

Conclusion: The proposed method provides robust correction of both Nyquist ghost and geometric distortion in EPI, and it is particularly suitable for dynamic EPI applications. Magn Reson Med 77:1749-1761, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

Keywords: EPI artifacts; Nyquist ghost correction; fMRI; geometric distortion correction; parallel imaging.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources