Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2016 Jul;47(7):1472-7.
doi: 10.1016/j.injury.2016.04.003. Epub 2016 Apr 20.

Galeazzi fractures: Is DRUJ instability predicted by current guidelines?

Affiliations
Comparative Study

Galeazzi fractures: Is DRUJ instability predicted by current guidelines?

Tony Tsismenakis et al. Injury. 2016 Jul.

Abstract

Introduction: Clinically significant distal radioulnar joint (DRUJ) injuries can occur with radial shaft fractures. Several radiographic methods of diagnosis, such as radial shortening of >5mm or fracture line within 7.5cm from the lunate facet, have been proposed but not clinically validated. The purpose of this study was to compare radiographic measurements of radial shaft fractures associated with and without clinically significant DRUJ injury (i.e., true Galeazzi fracture-dislocation) in order to evaluate the predictive value of reported parameters of DRUJ injury.

Patients and methods: A retrospective record and radiographic review was performed of 66 consecutive skeletally mature patients with isolated radial shaft fractures from 2004 to 2014 treated at one level 1 academic trauma center. Intraoperatively determined DRUJ instability after radial shaft fixation was used as the gold standard for diagnosis of a Galeazzi fracture-dislocation.

Results: Average age was 34 years old (range: 18-90). By thirds, there were 10 proximal (15%), 27 middle (41%), and 29 distal (44%) fractures. 13 (20%) had an associated ulnar styloid fracture. 7 (11%) patients had DRUJ instability after radial fixation. Radial shortening averaged 4.4±5.2mm (-2.6-22), and 21 had shortening of >5mm. Twenty-six (39%) fractures were within 7.5cm of the wrist joint. Previous guidelines were only moderately accurate. Even greater shortening did not predict instability (3/7 patients with >10mm shortening had a true injury). Four out of 7 cases with instability had ulnar styloid fractures (p=0.02).

Discussion and conclusions: Using a larger data set than has historically been evaluated, previously reported radiographic guidelines are only moderately accurate. The presence of an ulnar styloid fracture can be helpful. Surgeons should be aware of these associations but rely primarily on intraoperative assessment of the DRUJ after radial fixation to determine treatment.

Keywords: DRUJ; DRUJ dislocation; Galeazzi; Galeazzi fracture; Radial shaft fracture.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms