Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2016 Jul;22(7):613-9.
doi: 10.1016/j.cmi.2016.04.010. Epub 2016 Apr 29.

Added value of molecular assay Xpert MTB/RIF compared to sputum smear microscopy to assess the risk of tuberculosis transmission in a low-prevalence country

Affiliations
Free article
Comparative Study

Added value of molecular assay Xpert MTB/RIF compared to sputum smear microscopy to assess the risk of tuberculosis transmission in a low-prevalence country

O Opota et al. Clin Microbiol Infect. 2016 Jul.
Free article

Abstract

Airborne precautions are required at hospital admission for patients with suspected pulmonary tuberculosis. The isolation is maintained until 3 serially collected sputum smears are acid-fast bacilli negative, a time- and labor-intensive method with limited sensitivity and specificity, which has a great impact on patient flow management. We evaluated the possibility of replacing the result of microscopy by the semiquantitative result of the molecular point-of-care test Xpert MTB/RIF to assess patients' transmission risk to quickly guide airborne isolation decisions in low-endemic countries. The performance of the Xpert MTB/RIF, used as a first-line test, was compared to the results of microscopy for specimens (n=242) collected from May 2010 to December 2014 in Lausanne, Switzerland. The sensitivity and specificity of Xpert MTB/RIF were 91.5% (65/71) and 99.6% (170/171), respectively, vs. 64.8% (46/71) and 94.2% (161/171) for microscopy. Samples with negative Xpert MTB/RIF were all smear negative for Mycobacterium tuberculosis (negative predictive value, 100%). The semiquantitative results of Xpert MTB/RIF-high, medium, low or very low-were found to correlate with acid-fast bacilli detection: positive predictive value of 100% (6/6), 96.5% (27/28), 52.2% (12/23) and 11.1% (1/9) respectively. Finally, when including clinical criteria, we identified 11 smear-negative but Xpert MTB/RIF-positive patients with a significant transmission potential. In conclusion, our data support the introduction of an Xpert MTB/RIF-based strategy as a replacement of smear microscopy for a faster and more accurate management of tuberculosis patients' transmission risk in a low-prevalence country.

Keywords: Acid-fast bacilli staining; Molecular POCT; Molecular diagnostic; Real-time PCR; Transmissibility; Tuberculosis diagnosis; Xpert MTB/RIF.

PubMed Disclaimer

LinkOut - more resources