Relationship Between Anticoagulation Intensity and Thrombotic or Bleeding Outcomes Among Outpatients With Continuous-Flow Left Ventricular Assist Devices
- PMID: 27154497
- PMCID: PMC4860612
- DOI: 10.1161/CIRCHEARTFAILURE.115.002680
Relationship Between Anticoagulation Intensity and Thrombotic or Bleeding Outcomes Among Outpatients With Continuous-Flow Left Ventricular Assist Devices
Abstract
Background: We evaluated thrombotic and bleeding outcomes in patients with continuous-flow left ventricular assist devices (CF-LVADs), stratified by anticoagulation intensity. Previous studies of outpatients with CF-LVADs have suggested that target international normalized ratio (INR) values <2.5 (range, 2-3) may be used. However, recent studies reported an increase in pump thrombosis among CF-LVADs, especially within the first 6 months of implant.
Methods and results: We retrospectively reviewed 249 outpatients at our center who received a CF-LVAD between January 2005 and August 2013. Using Poisson models, we analyzed their 10 927 INRs to determine INR-specific rates of thrombotic (ischemic stroke and suspected pump thrombosis) and hemorrhagic (gastrointestinal bleeding and hemorrhagic stroke) events occurring outside of the hospital. In multivariate analyses, we adjusted for age, sex, atrial fibrillation, coronary disease, and LVAD type as time-dependent Cox proportional hazard models. During a mean follow-up of 17.6±13.6 months, thrombotic events occurred in 46 outpatients. The highest event rate (0.40 thrombotic events per patient-year) was in the INR range of <1.5, but INR values of 1.5 to 1.99 also had high rates (0.16 thrombotic events per patient-year). INR was inversely associated with thrombotic events (hazard ratio, 0.40; 95% confidence interval, 0.22-0.72; P=0.002). The optimal INR based on weighted mortality of thrombotic and bleeding events was 2.6.
Conclusions: INR is inversely related to thrombotic events occurring outside of the hospital among patients supported with CF-LVADs. INR values <2.0 increase the rate of thrombotic events occurring outside of the hospital among patients supported with CF-LVADs.
Keywords: atrial fibrillation; follow-up studies; hemorrhage; international normalized ratio stroke.
© 2016 American Heart Association, Inc.
Conflict of interest statement
GAE receives consulting fees from Thoratec. No other relevant conflicts. Content is solely the responsibility of the authors.
Figures
Comment in
-
On Target: Optimum International Normalized Ratio for Left Ventricular Assist Device Patients.Circ Heart Fail. 2016 May;9(5):e003166. doi: 10.1161/CIRCHEARTFAILURE.116.003166. Circ Heart Fail. 2016. PMID: 27154498 No abstract available.
References
-
- Kirklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Timothy Baldwin J, Young JB. Fifth INTERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2013;32:141–56. - PubMed
-
- Slaughter MS, Rogers JG, Milano CA, Russell SD, Conte JV, Feldman D, Sun B, Tatooles AJ, Delgado RM, 3rd, Long JW, Wozniak TC, Ghumman W, Farrar DJ, Frazier OH HeartMate III. Advanced heart failure treated with continuous-flow left ventricular assist device. The New England journal of medicine. 2009;361:2241–51. - PubMed
-
- Griffith BP, Kormos RL, Borovetz HS, Litwak K, Antaki JF, Poirier VL, Butler KC. HeartMate II left ventricular assist system: from concept to first clinical use. The Annals of thoracic surgery. 2001;71:S116–20. discussion S114-6. - PubMed
-
- Boyle AJ, Russell SD, Teuteberg JJ, Slaughter MS, Moazami N, Pagani FD, Frazier OH, Heatley G, Farrar DJ, John R. Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: analysis of outpatient anti-coagulation. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2009;28:881–7. - PubMed
-
- John R, Kamdar F, Liao K, Colvin-Adams M, Miller L, Joyce L, Boyle A. Low thromboembolic risk for patients with the Heartmate II left ventricular assist device. The Journal of thoracic and cardiovascular surgery. 2008;136:1318–23. - PubMed