Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 May 1;32(5):290-7.
doi: 10.3928/1081597X-20160310-01.

Long-term Visual and Refractive Outcomes After LASIK for High Myopia and Astigmatism From -8.00 to -14.25 D

Long-term Visual and Refractive Outcomes After LASIK for High Myopia and Astigmatism From -8.00 to -14.25 D

Dan Z Reinstein et al. J Refract Surg. .

Abstract

Purpose: To evaluate outcomes of high myopic LASIK using the MEL 80 excimer laser (Carl Zeiss Meditec, Jena, Germany).

Methods: Retrospective analysis of 479 consecutive high myopic LASIK procedures (318 patients) using the MEL 80 excimer laser and VisuMax femtosecond laser (Carl Zeiss Meditec) in 77% of cases or zero compression Hansatome microkeratome (Bausch & Lomb, Rochester, NY) in 23% of cases. Inclusion criteria were preoperative spherical equivalent refraction (SEQ) of between -8.00 and -14.25 diopters (D) and corrected distance visual acuity (CDVA) of 20/20 or better. Patients were observed for a minimum of 1 year. Flap thickness was between 80 and 160 µm and optical zone was between 5.75 and 6.50 mm. Standard outcomes analysis was performed.

Results: Mean attempted SEQ was -9.39 ± 1.22 D (range: -8.00 to -14.18 D) and mean cylinder was -1.03 ± 0.84 D (range: 0.00 to -4.50 D). Mean age was 37 ± 9 years (range: 21 to 60 years) with 54% female patients. Postoperative SEQ was ±0.50 D in 55% and ±1.00 D in 83% of eyes after primary treatment. After re-treatment, 69% of eyes were within ±0.50 D and 95% were within ±1.00 D. UDVA was 20/20 or better in 89% of eyes after final treatment. One line of CDVA was lost in 3% of eyes and no eyes lost two or more lines. Statistically significant increases (P < .001) were measured in contrast sensitivity (CSV-1000) at 12 and 18 cycles per degree.

Conclusions: The MEL 80 excimer laser was found to achieve high efficacy and safety for treatment of high myopia between -8.00 and -14.25 D and up to -4.50 D of cylinder. [J Refract Surg. 2016;32(5):290-297.].

PubMed Disclaimer

LinkOut - more resources