Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Dec;13(6):693-699.
doi: 10.1080/15412555.2016.1174985. Epub 2016 May 12.

Exercise Ventilation in COPD: Influence of Systolic Heart Failure

Affiliations
Free article

Exercise Ventilation in COPD: Influence of Systolic Heart Failure

Flavio F Arbex et al. COPD. 2016 Dec.
Free article

Abstract

Systolic heart failure is a common and disabling co-morbidity of chronic obstructive pulmonary disease (COPD) which may increase exercise ventilation due to heightened neural drive and/or impaired pulmonary gas exchange efficiency. The influence of heart failure on exercise ventilation, however, remains poorly characterized in COPD. In a prospective study, 98 patients with moderate to very severe COPD [41 with coexisting heart failure; 'overlap' (left ventricular ejection fraction < 50%)] underwent an incremental cardiopulmonary exercise test (CPET). Compared to COPD, overlap had lower peak exercise capacity despite higher FEV1. Overlap showed lower operating lung volumes, greater ventilatory inefficiency and larger decrements in end-tidal CO2 (PETCO2) (P < 0.05). These results were consistent with those found in FEV1-matched patients. Larger areas under receiver operating characteristic curves to discriminate overlap from COPD were found for ventilation ([Formula: see text]E)-CO2 output [Formula: see text]CO2) intercept, [Formula: see text]E-[Formula: see text]CO2 slope, peak [Formula: see text]E/[Formula: see text]CO2 ratio and peak PETCO2. Multiple logistic regression analysis revealed that [Formula: see text]CO2 intercept ≤ 3.5 L/minute [odds ratios (95% CI) = 7.69 (2.61-22.65), P < 0.001] plus [Formula: see text]E-[Formula: see text]CO2 slope ≥ 34 [2.18 (0.73-6.50), P = 0.14] or peak [Formula: see text]E/[Formula: see text]CO2 ratio ≥ 37 [5.35 (1.96-14.59), P = 0.001] plus peak PETCO2 ≤ 31 mmHg [5.73 (1.42-23.15), P = 0.01] were indicative of overlapping. Heart failure increases the ventilatory response to metabolic demand in COPD. Variables reflecting excessive ventilation might prove useful to assist clinical interpretation of CPET responses in COPD patients presenting heart failure as co-morbidity.

Keywords: Carbon dioxide; cardiopulmonary exercise testing; dyspnoea; exertion; gas exchange.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources