Patient crossover and potentially avoidable repeat computed tomography exams across a health information exchange
- PMID: 27178985
- PMCID: PMC5201178
- DOI: 10.1093/jamia/ocw035
Patient crossover and potentially avoidable repeat computed tomography exams across a health information exchange
Abstract
Objective: The purpose of this study was to measure the number of repeat computed tomography (CT) scans performed across an established health information exchange (HIE) in New York City. The long-term objective is to build an HIE-based duplicate CT alerting system to reduce potentially avoidable duplicate CTs.
Methods: This retrospective cohort analysis was based on HIE CT study records performed between March 2009 and July 2012. The number of CTs performed, the total number of patients receiving CTs, and the hospital locations where CTs were performed for each unique patient were calculated. Using a previously described process established by one of the authors, hospital-specific proprietary CT codes were mapped to the Logical Observation Identifiers Names and Codes (LOINC®) standard terminology for inter-site comparison. The number of locations where there was a repeated CT performed with the same LOINC code was then calculated for each unique patient.
Results: There were 717 231 CTs performed on 349 321 patients. Of these patients, 339 821 had all of their imaging studies performed at a single location, accounting for 668 938 CTs. Of these, 9500 patients had 48 293 CTs performed at more than one location. Of these, 6284 patients had 24 978 CTs with the same LOINC code performed at multiple locations. The median time between studies with the same LOINC code was 232 days (range of 0 to 1227); however, 1327 were performed within 7 days and 5000 within 30 days.
Conclusions: A small proportion (3%) of our cohort had CTs performed at more than one location, however this represents a large number of scans (48 293). A noteworthy portion of these CTs (51.7%) shared the same LOINC code and may represent potentially avoidable studies, especially those done within a short time frame. This represents an addressable issue, and future HIE-based alerts could be utilized to reduce potentially avoidable CT scans.
Keywords: avoidable; computed tomography; crossover; electronic health records; health information exchange.
© The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Figures

Similar articles
-
Standard Anatomic Terminologies: Comparison for Use in a Health Information Exchange-Based Prior Computed Tomography (CT) Alerting System.JMIR Med Inform. 2017 Dec 14;5(4):e49. doi: 10.2196/medinform.8765. JMIR Med Inform. 2017. PMID: 29242174 Free PMC article.
-
Assessing the performance of LOINC® and RadLex for coverage of CT scans across three sites in a health information exchange.AMIA Annu Symp Proc. 2013 Nov 16;2013:94-102. eCollection 2013. AMIA Annu Symp Proc. 2013. PMID: 24551324 Free PMC article.
-
Mapping of HIE CT terms to LOINC®: analysis of content-dependent coverage and coverage improvement through new term creation.J Am Med Inform Assoc. 2019 Jan 1;26(1):19-27. doi: 10.1093/jamia/ocy135. J Am Med Inform Assoc. 2019. PMID: 30445562 Free PMC article.
-
LOINC codes for hospital information systems documents: a case study.J Am Med Inform Assoc. 2009 May-Jun;16(3):400-3. doi: 10.1197/jamia.M2882. Epub 2009 Mar 4. J Am Med Inform Assoc. 2009. PMID: 19261942 Free PMC article.
-
Logical Observation Identifiers Names and Codes for Laboratorians.Arch Pathol Lab Med. 2020 Feb;144(2):229-239. doi: 10.5858/arpa.2018-0477-RA. Epub 2019 Jun 20. Arch Pathol Lab Med. 2020. PMID: 31219342 Review.
Cited by
-
The LOINC RSNA radiology playbook - a unified terminology for radiology procedures.J Am Med Inform Assoc. 2018 Jul 1;25(7):885-893. doi: 10.1093/jamia/ocy053. J Am Med Inform Assoc. 2018. PMID: 29850823 Free PMC article.
-
Standard Anatomic Terminologies: Comparison for Use in a Health Information Exchange-Based Prior Computed Tomography (CT) Alerting System.JMIR Med Inform. 2017 Dec 14;5(4):e49. doi: 10.2196/medinform.8765. JMIR Med Inform. 2017. PMID: 29242174 Free PMC article.
-
Factors associated with imaging overuse in the emergency department: A systematic review.Am J Emerg Med. 2018 Feb;36(2):301-309. doi: 10.1016/j.ajem.2017.10.049. Epub 2017 Oct 25. Am J Emerg Med. 2018. PMID: 29100783 Free PMC article.
-
Hospitals' adoption of intra-system information exchange is negatively associated with inter-system information exchange.J Am Med Inform Assoc. 2018 Sep 1;25(9):1189-1196. doi: 10.1093/jamia/ocy058. J Am Med Inform Assoc. 2018. PMID: 29860502 Free PMC article.
-
Towards the elimination of chronic obstructive pulmonary disease: a Lancet Commission.Lancet. 2022 Sep 17;400(10356):921-972. doi: 10.1016/S0140-6736(22)01273-9. Epub 2022 Sep 5. Lancet. 2022. PMID: 36075255 Free PMC article. Review.
References
-
- Bourgeois FC, Olson KL, Mandl KD. Patients treated at multiple acute health care facilities: quantifying information fragmentation. Arch Int Med. 2010;170(22): 1989–1995. - PubMed
-
- Hillestad R, Bigelow J, Bower A, et al. Can electronic medical record systems transform health care? Potential health benefits, savings, and costs. Health Aff. 2005;24(5):1103–1117. - PubMed
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials