Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Jul 15:126:75-82.
doi: 10.1016/j.jpba.2016.04.039. Epub 2016 Apr 29.

Development and validation of a rapid and sensitive UPLC-MS/MS method for determination of uracil and dihydrouracil in human plasma

Affiliations

Development and validation of a rapid and sensitive UPLC-MS/MS method for determination of uracil and dihydrouracil in human plasma

Bart A W Jacobs et al. J Pharm Biomed Anal. .

Abstract

Quantification of the endogenous dihydropyrimidine dehydrogenase (DPD) substrate uracil (U) and the reaction product dihydrouracil (UH2) in plasma might be suitable for identification of patients at risk of fluoropyrimidine-induced toxicity as a result of DPD deficiency. In this paper, we describe the development and validation of a rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay for quantification of U and UH2 in human plasma. Analytes were extracted by protein precipitation, chromatographically separated on an Acquity UPLC(®) HSS T3 column with gradient elution and analyzed with a tandem mass spectrometer equipped with an electrospray ionization source. U was quantified in the negative ion mode and UH2 in the positive ion mode. Stable isotopes for U and UH2 were used as internal standards. Total chromatographic run time was 5min. Validated concentration ranges for U and UH2 were from 1 to 100ng/mL and 10 to 1000ng/mL, respectively. Inter-assay bias and inter-assay precision for U were within ±2.8% and ≤12.4%. For UH2, inter-assay bias and inter-assay precision were within ±2.9% and ≤7.2%. Adequate stability of U and UH2 in dry extract, final extract, stock solution and plasma was demonstrated. Stability of U and UH2 in whole blood was only satisfactory when stored up to 4hours at 2-8°C, but not at ambient temperatures. An accurate, precise and sensitive UPLC-MS/MS assay for quantification of U and UH2 in plasma was developed. This assay is now applied to support clinical studies with fluoropyrimidine drugs.

Keywords: 5-Fluorouracil; Capecitabine; Dihydropyrimidine dehydrogenase; Dihydrouracil; UPLC–MS/MS; Uracil.

PubMed Disclaimer

Publication types

MeSH terms