. 2016 Apr 13;8(4):e569.
doi: 10.7759/cureus.569.

Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio

Affiliations

Standardized Photographic Views in Oculoplastic Surgery: How to Capture Quality Images Outside a Photographic Studio

Chin T Ong et al. Cureus. .

Abstract

Purpose The aim of this paper is to demonstrate fundamental photographic techniques and standardized views in oculoplastic disease and surgery outside of a photographic studio. Methods A Canon EOS 60D digital single lens reflex (DSLR) camera, which was fitted with a Canon EF-S 60 mm USM macro lens, was used to photograph the subject. A Canon MR-14EX Macro Ringlite was used to illuminate the subject. Informed written consent was obtained for publication of the photographs used in this study. The photographs were taken in an ophthalmology clinic using standardized photographic settings at various magnification ratios. The magnification ratios were recalibrated and adjusted to accommodate the smaller sensor size in-line with standardized medical photography guidelines. Results We present a series of core views for various oculoplastic and orbital disease presentations. Conclusions It is possible to capture quality standardized digital photographs in a busy clinical environment without the need for a dedicated photographic studio.

Keywords: clinical photography; digital single lens reflex camera; photodocumentation; standardization.

PubMed Disclaimer

Conflict of interest statement

The authors have declared that no competing interests exist.

Figures

Figure 1
Figure 1. Eyelid views
Figure 2
Figure 2. Facial palsy views
Figure 3
Figure 3. Orbital views

References

    1. Pitfalls of nonstandardized photography. Archibald DJ, Carlson ML, Friedman O. Facial Plast Surg Clin North Am. 2010;18:253–266. - PubMed
    1. Standardized photography in facial plastic surgery: pearls and pitfalls. Becker DG, Tardy ME Jr. Facial Plast Surg. 1999;15:93–99. - PubMed
    1. Achieving standardized photographs in aesthetic surgery. Ellenbogen R, Jankauskas S, Collini FJ. Plast Reconstr Surg. 1990;86:955–961. - PubMed
    1. Making uniform photographic records in plastic surgery. Morello DC, Converse JM, Allen D. Plast Reconstr Surg. 1977;59:366–372. - PubMed
    1. Calibrating lenses for standard scales of reproduction with digital SLR cameras. Young S, Lake A. J Vis Commun Med. 2008;31:11–15. - PubMed

LinkOut - more resources