Comparison of Radiation Exposure Associated With Intraoperative Cone-Beam Computed Tomography and Follow-up Multidetector Computed Tomography Angiography for Evaluating Endovascular Aneurysm Repairs
- PMID: 27193306
- DOI: 10.1177/1526602816649588
Comparison of Radiation Exposure Associated With Intraoperative Cone-Beam Computed Tomography and Follow-up Multidetector Computed Tomography Angiography for Evaluating Endovascular Aneurysm Repairs
Abstract
Purpose: To compare the radiation exposure associated with intraoperative contrast-enhanced cone-beam computed tomography (ceCBCT) acquisitions to standard 3-phase multidetector computed tomography (MDCT) angiography used for assessing technical success after endovascular aortic repair (EVAR).
Methods: Effective doses (EDs) were calculated for 66 EVAR patients (mean age 71 years; 61 men) with a mean 27.7-kg/m(2) body mass index (range 17-49) who had both intraoperative ceCBCT and postoperative 3-phase MDCT angiography between November 2012 and April 2015. In addition, EDs were directly determined using thermoluminescent dosimeters (TLDs) embedded in anthropomorphic phantoms with body mass indexes of 22 and 30 kg/m(2) Effective doses were calculated by summing doses recorded by all TLDs corresponding to a specific tissue type before applying the International Commission on Radiological Protection (ICRP) 60 and 103 weighting factors. EDs were compared with each other for both imaging modalities as well as to TLD measurements.
Results: Average EDs of the patient collective were 4.9±1.1 mSv for ceCBCT, 2.6±1.2 mSv for single-phase MDCT (46% decrease, covering solely the area of the implanted endograft), and 13.6±5.5 mSv for comprehensive 3-phase MDCT examinations (178% increase, anatomical coverage from the aortic arch to femoral artery bifurcation). EDs determined in phantom measurements ranged from 3.1 to 4.5 mSv for ceCBCT, amounting to 2.6 mSv for a single MDCT phase (15% to 40% decrease) using ICRP 60 conversion factors. Applying ICRP 103 factors resulted in higher values for ceCBCT and slightly lower ones for MDCT.
Conclusion: ceCBCT offers the chance for immediate intraoperative revisions of endograft-related problems. Requiring only a single-phase acquisition, ceCBCT is associated with a considerable reduction in ED (50%-75%) compared to standard 3-phase MDCT angiography after EVAR. On the other hand, MDCT has a larger field of view and is associated with less radiation exposure for a single phase (reduction of 20%-60%) if only the stented region is covered; however, MDCT angiography also uses larger amounts of contrast.
Keywords: DynaCT; abdominal aortic aneurysm; anthropomorphic phantom; computed tomography angiography; cone beam computed tomography; effective dose; endovascular aneurysm repair; surveillance imaging.
© The Author(s) 2016.
Similar articles
-
Intraoperative contrast-enhanced cone beam computed tomography to assess technical success during endovascular aneurysm repair.J Vasc Surg. 2016 Sep;64(3):577-84. doi: 10.1016/j.jvs.2016.02.045. Epub 2016 Apr 19. J Vasc Surg. 2016. PMID: 27106245
-
Impact of onlay fusion and cone beam computed tomography on radiation exposure and technical assessment of fenestrated-branched endovascular aortic repair.J Vasc Surg. 2019 Apr;69(4):1045-1058.e3. doi: 10.1016/j.jvs.2018.07.040. Epub 2018 Dec 4. J Vasc Surg. 2019. PMID: 30527938
-
Prospective nonrandomized study to evaluate cone beam computed tomography for technical assessment of standard and complex endovascular aortic repair.J Vasc Surg. 2020 Jun;71(6):1982-1993.e5. doi: 10.1016/j.jvs.2019.07.080. Epub 2019 Oct 11. J Vasc Surg. 2020. PMID: 31611108
-
Pros and Cons of 3D Image Fusion in Endovascular Aortic Repair: A Systematic Review and Meta-analysis.J Endovasc Ther. 2017 Aug;24(4):595-603. doi: 10.1177/1526602817708196. Epub 2017 May 9. J Endovasc Ther. 2017. PMID: 28485198
-
Imaging of the endoleak after endovascular aneurysm repair procedure by using multidetector computer tomography angiography.J Cardiovasc Surg (Torino). 2009 Aug;50(4):515-26. J Cardiovasc Surg (Torino). 2009. PMID: 19734835 Review.
Cited by
-
Combined Angio-CT Systems: A Roadmap Tool for Precision Therapy in Interventional Oncology.Radiol Imaging Cancer. 2021 Sep;3(5):e210039. doi: 10.1148/rycan.2021210039. Radiol Imaging Cancer. 2021. PMID: 34559007 Free PMC article. Review.
-
A State-of-the-Art Review of Intra-Operative Imaging Modalities Used to Quality Assure Endovascular Aneurysm Repair.J Clin Med. 2023 Apr 28;12(9):3167. doi: 10.3390/jcm12093167. J Clin Med. 2023. PMID: 37176608 Free PMC article. Review.
-
Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT-angiography suite.J Appl Clin Med Phys. 2020 Feb;21(2):121-127. doi: 10.1002/acm2.12808. Epub 2020 Jan 10. J Appl Clin Med Phys. 2020. PMID: 31922349 Free PMC article.
-
Imaging Techniques to Aid IR Treatment of Musculoskeletal Malignancy.Semin Intervent Radiol. 2019 Mar;36(1):49-62. doi: 10.1055/s-0039-1679952. Epub 2019 Mar 29. Semin Intervent Radiol. 2019. PMID: 30936620 Free PMC article. Review. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources